4. Fasten the side handle securely by turning the grip until tight.

5.2.2 Fitting the depth gauge

1. Unplug the supply cord from the power outlet.
2. Release the side handle clamping band by turning the handle counterclockwise.
3. Slide the depth gauge from the front into the opening provided in the side handle.
4. Set the depth gauge to the desired depth.
5. Secure the depth gauge by turning the grip of the side handle until tight.

5.2.3 Fitting the spray guard

WARNING
Risk of electric shock! If the machine is used for hand-guided drilling in an upwards direction without
the necessary safety precautions, water may enter the machine and present a risk of electric shock.
▶ When carrying out hand-guided drilling in an upwards direction, always use a water collection
system with a wet/dry industrial vacuum cleaner and the spray guard.
1. Disconnect the supply cord plug from the power outlet.
2. Slide the spray guard over the chuck from the front and push it onto the gear housing on the drilling
machine.

5.2.4 Fitting the water collector holder

Note
Drilling is permissible only under the following conditions:
The supplied water collector holder is fitted and adjusted to match the length of the core bit used.
A core bit sealing ring that matches the diameter of the core bit must be fitted in the water collector
holder.