Fieldbus
Fieldbus Variable
Block
Name
Index
28
BACKOFF_EFFORT
29
SPOOL_POSITION
30
SPOOL_EFFORT
31
PIEZO_OFFSET
32
PEIZO_COMMAND
21
PRESSURE_SUPPLY
22
PRESSURE_PORT_A XDTB_MAIN
23
PRESSURE_PORT_B XDTB_MAIN
79
PRESSURE_
DIFFERENTIAL
101
FINAL_VALUE_
RANGE
Control: Configuration & Gain Parameters
107
CONTROL_CONFIG
87
CURVE_SELECT
28
P_GAIN
35
P_GAIN_EFFECTIVE
36
P_GAIN_MULT
29
I_GAIN
30
D_GAIN
37
D_GAIN_EFFECTIVE
38
D_GAIN_FILTER
31
PRESS_CTRL_
GAIN_MAX
39
PRESS_CTRL_
GAIN_EFFECTIVE
40
PRESS_CTRL_
GAIN_MULT
41
PRESS_CTRL_SP
26
Transducer
Fieldbus
Block
Datatypes
Register
XDTB_TECH
FLOAT
20
XDTB_TECH
FLOAT
21
XDTB_TECH
FLOAT
22
XDTB_TECH
FLOAT
24
XDTB_TECH
FLOAT
25
XDTB_MAIN
FLOAT
27
FLOAT
28
FLOAT
29
XDTB_MD
FLOAT
30
XDTB_MAIN
RECORD
N/A
XDTB_MAIN
BIT_STRING
38
XDTB_TECH
UNSIGNED 8
39
XDTB_MAIN
FLOAT
40
XDTB_TECH
FLOAT
41
XDTB_TECH
FLOAT
42
XDTB_MAIN
INTEGER 16
44
XDTB_MAIN
UNSIGNED 16
46
XDTB_TECH
UNSIGNED 16
47
XDTB_TECH
UNSIGNED 16
48
XDTB_MAIN
FLOAT
50
XDTB_TECH
FLOAT
51
XDTB_TECH
FLOAT
52
XDTB_TACH
FLOAT
53
Logix 3400MD Digital Positioner FCD LGENIM3404-00 – 9/09
Logix Positioner
Fix
Type
Pt
Variable Name
Rd
S_LONG
NO
Hall_Sum
S_INT
/100
Hall_Pct
S_INT
/100
reserved for
spool effort
S_INT
/100
Pzv_Null
S_INT
/100
Pzv_Cmd
U_LONG
/100
PS_Supply_Press
S_INT
/100
PS1_Pct
S_INT
/100
PS2_pct
S_INT
/100
PS_Delta_Pct
N/A
N/A
N/A
U_CHAR
NO
Control_Config
U_CHAR
NO
Curve_Select
S_INT
/100
PGain_Max
S_INT
/100
Pgain_Instant
S_INT
/1000 PGain_Mult
S_INT
NO
IGAIN
U_INT
NO
DT_Gain_Max
U_INT
NO
DT_Gain_Cur
S_INT
NO
DT_Depth
S_INT
/10
PS_Gain_Max
S_INT
/10
PS_Gain_Cur
S_INT
/100
PS_Mult
S_INT
NO
PS_Target
R/W
Description
R
Status, memory Backoff, Control
Term Value
R
Status, Memory Backoff, Relay
Instant Position
R
Status, Memory Backoff, Relay
Instant Position
R
Status, Piezo, Output Percent @ Null
R
Status, Piezo, Output Voltage in
Percent
R
Supply Pressure in User Units (Only
active in Advanced or Pro Models)
R
Port A Pressure in User Units (Only
active in Advanced or Pro Models)
R
Port B Pressure in User Units (Only
Active in Advanced or Pro Models)
R
Status, Pressure, Delta, Port 1-Port 2
SRW
Used to limit the command position
received from the AO block. FB Only
Parameter.
NRW
Setup, Valve Configuration (Std/Adv,
DA/SA, etc.)
SRW
Select Characterization type when
the Characterization DIP switch is set
to 'Other'
SRW
Setup, Gain Proportional, Maximum
R
Control, Gain, Proportional,
Instantaneous
SRW
Setup, Gain, Proportional, Multiplier
SRW
Setup, Gain, Integral
SRW
Setup, Gain, Derivitive, Basic
R
Status, Gain, Derivitive,
Instantaneous
SRW
Setup, Gain, Derivitive, Depth
SRW
Setup, Pressure Control, Gain, Basic
R
Status, Pressure Control, Gain,
Instantaneous
SRW
Setup, Pressure Control, Gain,
Multiplier
SRW
Status Pressure Control, Target
Differential