Error 04-1: Punch rejected
The timeclock has detected that the time span since the last punch for this
employee does not meet the minimum time between punches. The minimum time
is configured using your host application software.
Wait the appropriate amount of time, then punch again.
Error 04-2: Last punch invalid
The date and time of the last punch for this employee is in the future, making
schedule enforcement impossible.
Perform a Delete All Punches transaction in Maintenance Mode. For more
information, see "Delete All Punches" in Chapter 4 on page 4-58. If data was
already collected from the timeclock, you need to correct the data in the host
application.
Error 05-1: Punch rejected (xxx)
Schedule enforcement logic has determined that the employee cannot punch. This
error includes a reason (xxx) for the rejection.
Values include:
101 - Schedule enforcement is disabled but a repunch error was detected
102 - The restriction profile the employee is assigned to is not available (not
downloaded by DCM)
103 - The generic schedule the employee is assigned to is not available (not
downloaded by DCM)
104 - The last punch is in the future (see Error 04-2)
105 - Repunch error (see Error 04-1)
106 - An error was found in the data in the generic schedule the employee is
assigned to