Appendices
Event code
Event name
(hex)
84B20000
EtherCAT Illegal
State Change Error
84B40000
Synchronization
Error
84B50000
Sync Manager WDT
Error
84B60000
ESC Initialization
Error
84B70000
SII Verification Error
84B90000
Synchronization
Interruption Error
84BA 0000
Bootstrap State
Transition Request
Error
88100000
Communications
Synchronization
Error
88120000
Safety Communica-
tions Timeout
A - 106
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User's Manual (I586)
Description
An undefined communica-
tions state change com-
mand was received.
A signal for synchronous
communications could not
be detected.
PDO communications were
interrupted for the allow-
able period or longer.
The initialization of Ether-
CAT slave communications
controller failed.
An error occurred in SII data
of the EtherCAT slave com-
munications controller.
Synchronization interrup-
tion did not occur within the
specified period.
The state transition to
unsupported Bootstrap was
requested.
Communications were not
established consecutively
because the synchroniza-
tion with the EtherCAT Mas-
ter could not be achieved.
A communications timeout
occurred in safety process
data communications with
the Safety CPU Unit.
Assumed cause
• An undefined communica-
tions state change com-
mand was received
• Noise
• Error of the EtherCAT slave
communications controller
• An EtherCAT communica-
tions cable is disconnected,
loose, or broken
• Host controller error
• Data was incorrectly over-
written in the non-volatile
memory of the EtherCAT
slave communications con-
troller
• Failure of the EtherCAT
slave communications con-
troller
• Data was incorrectly over-
written in the non-volatile
memory of the EtherCAT
slave communications con-
troller
• Failure of the EtherCAT
slave communications con-
troller or false detection
• Incorrect EtherCAT syn-
chronization setting of the
host controller
• Failure of the EtherCAT
slave communications con-
troller or false detection
• The EtherCAT master
requested the transition of
unsupported Bootstrap
• The power supply to the
host controller was inter-
rupted during PDO commu-
nications
• An EtherCAT communica-
tions cable is disconnected,
loose, broken, or has a con-
tact failure
• Noise
• A setting is not correct. The
setting of the safety task
period of the Safety CPU
Unit is too short
• There is excessive noise
• The Safety CPU Unit or
safety slave entered a sta-
tus where it could not con-
tinue safety process data
communications
Level
Refer-
ence
P. A-152
P. A-153
P. A-153
P. A-154
P. A-154
P. A-155
P. A-155
P. A-156
P. A-157