Stratix Memory Board II
segment display should start counting. LED 0 is the error indicator. If it goes out
the test has failed. The counter will run until the seven segment display reads 80.
At this point if LED 0 is still on the test has passed.

3.6 Downloading Factory Image

If you have corrupted the factory image pre-loaded into the on board flash memory
you will have to reload the data. Set ALL DIP switch positions on S8 to the OFF
position.
Connect up a USB cable to a USB Blaster and connect the USB Blaster to the
JTAG port on the SMB1 board.
Run the "smb2_factory_image.bat" batch file. This will download the factory
image to the board. The process can take several minutes. The FCE (flash chip
enable) LED will blink until the download is complete.
After this is complete, turn the board power off by switching SW1 to the OFF
position. Turn SW1 back to the ON position. Push the SAFE push button (S3).
The Loading LED should blink, and the process should end with the SF (D14) and
the CONF_DONE (D13) should be on. If this is not the case, retry the process
ONCE.