Installation As An External Remote Control; Electrical Connection - Wolf BML Operating Instructions Manual

Table of Contents

Advertisement

Wall mounting base
installation
Wall mounting base
Mat. no. 2744275
Electrical connection of
remote control
Recommended cables
and
minimum cable
cross-sections:
Fuse/MCB protection:
8
Installation as an external remote
control
- Remove the wall mounting base from its packaging.
- Secure the wall mounting base on a flush-mounting box
(Ø 55 mm) or directly on the wall.
Fixing holes
Fixing holes
100
60
Wall mounting base
Installation of BML on wall mounting base
- The electrical connection must be carried out only by a qualified
electrician.
- Never route sensor leads alongside mains power cables.
- Use the repair switch to switch off the power supply
- Wire the wall mounting base with a four-core cable (minimum
cross-section 0.5 mm²) in accordance with the diagram
ϑ
Outside temperature sensor
eBUS
H05VV-F 3 x 2.5 mm²
H05VV-F 4 x 1.0 mm²
H05VV-F 2 x 0.5 mm²
Power supply 230 V 1 x 16 A
Terminal strip
Wall mounting base
power cable (230 V)
Open/Close servomotor 230 V
BUS cable (<400 m length)
3063527_201308