convenient. Customer can save and recall parameters quickly.
GRP1: This indicates saving power supply parameters in 1-9 groups.Press
(Shift)+
in corresponding groups.
GRP2: This indicates saving the parameters in 10-18 groups.Press
Recall
that the current number "1" represents parameters are saved in 10
groups.Number "2" represents the parameters are saved in 11
GRP3-GRP8 by parity of reasoning.
Detailed Save and Recall operation refer to chapter 3.7.
Timer Set (TIMER SET)
This item is used to set the "time on- load" function, time range 0.1-99999S .In
ON mode, the indicator light "Timer" will be lit on the VFD screen.When output
of power supply is opened, timer will begin to work, after reaching the definite
time,output will be off automatically.If in OFF mode,the timer function will not be
enabled.The default set is OFF.
Reset (RESET)
This item is used to reset all items in the menu.If you select YES, then unit will
restored to factory setting.If you select NO, all settings in the menu will remain
unchanged.
List (List Set)
IT6700 series power supply provides 9 list files, each list file includes 150 steps.
Before you edit a list file, please set the trigger mode:manual mode.
Press
key to select >SYST SET option,after that please push
confirm.At last to press direction key to select >Trig MANUAL and push
Enter
You can make the output change order by editing every step value of list
operation. The parameters you need to edit includes:single-step
voltage,single-step current,single-step delay time and whether to go on the next
step.Besides,you also need to set the repeat times and save list sequence
file.After the editing process,at this time if a trigger signal is received,power
supply will begin to work according to the sequence steps you've edit. Now we
take five steps for an example.
Operation steps:
1.
2.
3.
Recall
(Save) and the group number(1-9) can save the parameters
(Save)+saved group number(1-9)can save related parameters.Note
NOTE
IT6726G/IT6726H has 9×7 groups of memory capacities.
I-set
I-set
(Shift)+
button to confirm.
I-set
I-set
Press
(Shift) +
VFD display >MAX VOLT,press
to confirm
VFD display >LIST STATE,press
Enter
to confirm.
Copyright © Itech Electronics Co., Ltd.
(Menu)button to enter the menu,then press direction
(Menu)button to enter the menu.
to select >LIST SET,press
to select >LIST EDIT, press
Function
and Features
(Shift) +
th
th
groups.
Enter
button to
Enter
27
Need help?
Do you have a question about the IT6722 and is the answer not in the manual?