EXIT
POWER INFO MODEL
ITXXXX
VER
SN-1 XXXXXX the first six number of SN
SN-2 XXXXXX the middle six number of SN
SN-3 XXXXXX the last six number of SN
EXIT
EXIT MENU
Exit the main menu
Maximum voltage set(MAX VOLT)
The range of setting voltage is from 0V to rated voltage. You can press
(Shift) +
select >MAX VOLT item. Press
max voltage value, the output voltage value can only be set within the max
voltage. The default max voltage value is the rated value.
Over current protection set (OCP SET)
Over current protection feature allows the user to set an over current protection
point, when the current in the circuit is larger than the current protection point,
the power supply will enter OCP protection. Over current protection, power
output will be off, and accompanied by the chirping of the buzzer, the VFD mark
Prot will be lit, and the emergence of "OVER CURR" alarm
The operation to set the OCP point:
1.
2.
3.
4.
Charge-mode function set (CHANG)
This function is used for IT6726C power to battery charging. When ON option is
selected, the power output is turned off after completing the battery charge,
meanwhile the power will not reverse current, that is to say the battery will not
VSET
Set the voltage for present step
ISET
Set the current for present step
SEC
Setup single step delay time (0.1-9999)
YES
NEXT
(YES)
NO
REPET
1-65535
NO
SAVE
FILE0-FILE9
Exit the system menu
Unit model
the software version
Exit the information menu
NOTE
ESC
Pressing
button can enable you to quit any function setting.
I-set
I-set
(Menu) button to enter the menu, then press
I-set
I-set
Press
(Shift) +
、
Press
to overturn to OCP SET, press
、
Press
to select ON,press
Set OCP point by pressing numeric keys, then press
press
to escape.
Esc
Copyright © Itech Electronics Co., Ltd.
continue the edit of next step
End up the list file edit
Set the cycle count of list file
Un-save the current LIST file
Save the list file to appointed
memory
Enter
button to confirm. After you set the
(Menu)button to menu.
Enter
to confirm.
Function
and Features
、
key to
Enter
button to confirm.
Enter
. At last,
25
Need help?
Do you have a question about the IT6722 and is the answer not in the manual?