Configuration; Redundant Xhub Controller; Adding A Redundant Xhub Controller - Motorola DIMETRA MTS 4 Installation, Configuration, And Service Manual

Dimetra ip scalable (dips); dimetra ip compact (dipc)/scalable dimetra ip (sdip); dimetra ip micro/dimetra ip lite
Table of Contents

Advertisement

Applicant: Motorola Solutions

Configuration

No configuration in itself is needed for the module cage, but the Power Supply Unit needs to be configured and this is
described in
Updating the Mapping List with the New PSU TrackID on page
Installation and configuration of additional Base Radios are described separately in
Existing Module Cage in MTS 4 on page
Furthermore, if an additional Site Controller is ordered as a separate expansion kit, it needs to be installed and
configured, see

Redundant XHUB Controller

It is possible to add an redundant XHUB Controller to an MTS 4 Expansion Cabinet.
Note: In order to be able to expand to a redundant XHUB Controller, a redundant Site Controller must be
present in the MTS 4 Prime Cabinet.
The additional XHUB Controller is delivered with the expansion kit that includes required equipment and cables.

Adding a Redundant XHUB Controller

Procedure:
1 Wear an ESD strap and connect its cable to a verified good ground. This strap must be worn to prevent ESD
damage to any components.
2 Remove XHUB Controller blind plate if such exist in the upper module cage of the MTS 4 Expansion Cabinet.
3 Label the cables with labels included in the expansion kit.
4 Connect the Ethernet cables to the Base Radio(s) according to the scheme below:
Part no
3066544B02
3066544B15
3066544B16
3066544B01
5 Strap the cables.
6 Install the additional XHUB Controller. Use handle to slide the unit into the chassis.
7 Secure the XHUB Controller in the chassis with two M4X10 captive screws.
8 Connect the Ethernet cables to the unit as tagged earlier.
9 Connect the 3066544B12 cable that derives from the upper Site Controller in the MTS 4 Prime Cabinet (Exp Cab
connector).
10 Reconnect the power cables to the MTS Power Supply Units.
381.
Redundant Site Controller on page
Cable type
Ethernet cable
Ethernet cable
Ethernet cable
Ethernet cable
Note:
Ethernet cables stated above derives from the Base Radio(s) in the MTS 4 Expansion Cabinet.
At this stage only connect the cables to the Base Radio(s).
Important: Connect the ribbon cables at the rear before sliding the unit in to the chassis.
Equipment Type: ABZ89FC5827 / 109AB-5827
303.
389.
From
BR4 / SC2
BR1 / SC2
BR2 / SC2
BR3 / SC2
6802800U74-AD | September 2014 |
Expansion Options | 401
Additional Base Radio for
To
XHUB2 / BR4
XHUB2 / BR1
XHUB2 / BR2
XHUB2 / BR3
Send Feedback
Exhibit D2