6 Insert the additional Base Radio by aligning the side rails with the appropriate rail guides inside the Base Radio
chassis.
7 Gently push the additional module completely into the Base Radio chassis assembly using the module handle(s).
Be careful not to damage any of the cables previously connected when pushing the Base Radio into position.
8 Secure the additional module using two TORX screws. Tighten the screws to a torque of 2.7 Nm.
9 Connect the Power cables, Ethernet cable, Tx cable and Rx cables to the BR front plate.
10 Switch ON the Power Supply Unit. You do not need to do this if doing a hotswap.

Configuration

Basic configuration of base radios is needed when additional base radio(s) has been added to the MTS 4 cabinet. This
is described in
Note:
Base radios in the second Module Cage should be configured with <cabinet>:<position> set as
1:3 and 1:4.
Note: For configurations with Manual Tuned Cavity Combiner(s), the MTCC needs to be tuned after
adding additional Base Radio.
In addition to this, the following parameters need to be configured in TESS application:
Factory password
Field password
Cabinet ID
Position ID
Carrier Number (TX/RX frequencies are auto-generated based on Carrier Number setting)
Default TX Power level
Note: When these parameters have been configured in TESS Application and after the modified
configuration file has been uploaded to the Site Controller, the complete site needs to be reset to implement
the configuration change.

Redundant Site Controller

It is possible to add an additional (redundant) Site Controller to MTS 4. To add a redundant Site Controller, two
module cages must be present in the MTS 4.
Note: If a redundant Site Controller is added to an MTS with an expansion cabinet, a redundant XHUB
must also be added.
Note:
Redundant Site Controller feature is supported on releases:
and later.
The additional Site Controller is delivered with the expansion kit that includes required equipment and cables.
Note: If single or dual diversity, use QMA terminator (2866544A01) in unused Rx connectors on Base
Radio(s).
Configuring and Verifying the Base Radio on page
R6.0_001.12, MTS 05
R5.2_002.34, MTS 10
Equipment Type: ABZ89FC5827 / 109AB-5827
Expansion Options | 389
213.
6802800U74-AD | September 2014 |