Configure the DHCP Server

Timing

Display and set the clock timing source for the T1/E1 interface. The timing can
be either derived from the network (External) or provided to the T1 interface
by the V
2
IU (Internal). With a carrier-provided T1, the timing is usually
derived from the network (External, the default setting).
Mismatched timing modes can result in WAN connectivity but with intermittent data
loss.

Payload Loopback

Display and set the loopback setting. During T1 line testing the local interface
can be set to Loopback to allow the network provider to verify connectivity
and line quality. For normal operation the setting should always be No
Loopback (the default setting).
The 4350 can act as a DHCP server granting IP addresses to PCs, workstations,
servers or voice devices (IP phones, IADs or softphones) connected to its LAN
interfaces. DHCP is a protocol that enables IP devices to obtain temporary or
permanent IP addresses (out of a pool) from centrally administered servers.
The user can configure blocks of IP addresses, a default gateway, DNS servers,
NTP server address, Time offset from NTP value, WINS address and
TFTP/FTP server name that can be served to the requesting IP devices.