Application 2: Checkweighing O
Example: 1
Checkweighing samples with a target weight of 1250 g and a tolerance range from –10 g to +30 g
Settings (changes in the factory settings required for this example):
Application parameters: Application: Checkweighing
Setup: Printout:
PrtProt
:
7.6.
(see "Configuration" for options)
O
O
1240
O
66
; then select menu line item of your choice
1 Enter the initial target and
tolerance limit values
2 Place a sample equal to the
target weight (in this example,
1250 g) on the platform
3 Save target value
Signum 3 only:
4 Enter value for lower limit
(in this example, 1240 g)
5 Save value for the lower limit
1280
O
p
Setp
+
1.250 kg
Min
+
1.240 kg
Max
+
1.280 kg
G#
+
1.256 kg
T
+
0.000 kg
N
+
1.256 kg
Lim
+
0.48 %
W.Diff+
0.006 kg
-------------------
Signum 3 only:
6 Enter value for the upper limit
(in this example, 1280 g)
Save value for upper limit
7 Weigh samples
8 Print the results
Note: If automatic printout
of results is enabled, you do
not need to press the p key;
the results are printed auto-
matically.
Target
Minimum
Maximum
Gross weight
Tare weight
Net weight
Percentage of deviation
from target*
Absolute deviation from target
* Only in "Tolerance limits"
display mode:
If the weight is lighter than
the target, the display shows:
LL
If the weight is heavier than
the target, the display shows:
HH