SunStar SPS/A-3020 5030 SERIES User Manual page 99

Electronically controlled pattern sewing machine
Table of Contents

Advertisement

Function No. : 056
056. Decel Stitch
2~16 Stitch
Setting
Value
Function No. : 057
057. Decel SPM
200~500spm
Setting
Value
Function No. : 058
058. Trim Delay
52~1020ms
Setting
Value
Sewing
Function Name : Number of stitches to decelerate before ending work
It is to set the stitch number of when to deceleratebefore ending the work.
It is to set the number of stitches when the machine should decelerate.
(Factory installed condition : "2" )
[Contents] It is to set the number of stitches when the machine should start decelerating
before ending the operation.
Function Name : Decelerating speed before ending work
It is to set the speed the machine should decelerate before ending the work.
It is to set the speed to decelerate before ending the work.
(Factory installed condition : "400" )
[Contents] The speed must be decelerated before ending the work.
The decelerating speed is set here.
Function Name : Thread trimming delayed time
It is to set the delayed time before the wiper is operated after the thread is trimmed.
It is to set the delayed time after thread trimming. (Factory installed condition : " 72" )
[Contents] It is to set the delayed time of the wiper operation after the thread has been
cut.
Speed set
by user
speed
0
Stop
last stitch
command
sewed
[The ending Process of Sewing]
Set number of stitches sewed
for decelerating before ending(056)
Decelerated speed
before ending(057)
Thread trimming speed
Delayed time for thread trimming(058)
Thread
cut
Time
Wiper
operated
99