Frequency Jump (Pr. 31 To Pr. 36) - Mitsubishi Electric FR-E 500 Instruction Manual

Hide thumbs Also See for FR-E 500:
Table of Contents

Advertisement

" " Frequency jump (Pr. 31 to Pr. 36)

4.2.14 Frequency jump (Pr. 31 to Pr. 36)
Pr. 31 "frequency jump 1A"
Pr. 32 "frequency jump 1B"
Pr. 33 "frequency jump 2A"
Pr. 34 "frequency jump 2B"
Pr. 35 "frequency jump 3A"
Pr. 36 "frequency jump 3B"
! When it is desired to avoid resonance attributable to the natural frequency of a
mechanical system, these parameters allow resonant frequencies to be jumped. Up
to three areas may be set, with the jump frequencies set to either the top or bottom
point of each area.
! The value set to 1A, 2A or 3A is a jump point and operation is performed at this
frequency.
Parameter
Factory
Number
Setting
31
32
33
34
35
36
<Setting>
! To fix the frequency at 30Hz between Pr. 33 and
Pr. 34 (30Hz and 35Hz), set 35Hz in Pr. 34 and
30Hz in Pr. 33.
! To jump to 35Hz between 30 and 35Hz, set 35Hz in
Pr. 33 and 30Hz in Pr. 34.
Note: During acceleration/deceleration, the running frequency within the set area is
valid.
Setting Range
9999
0 to 400Hz, 9999
9999
0 to 400Hz, 9999
9999
0 to 400Hz, 9999
9999
0 to 400Hz, 9999
9999
0 to 400Hz, 9999
9999
0 to 400Hz, 9999
Frequency jump
Pr.36
Pr.35
Pr.34
Pr.33
Pr.32
Pr.31
Remarks
9999: Function invalid
9999: Function invalid
9999: Function invalid
9999: Function invalid
9999: Function invalid
9999: Function invalid
Pr.33:35Hz
Pr.34:30Hz
84
PARAMETERS
Pr.34:35Hz
Pr.33:30Hz

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e 520s ecFr-e 540 ec

Table of Contents