Mitsubishi Electric FR-E 500 Instruction Manual page 105

Hide thumbs Also See for FR-E 500:
Table of Contents

Advertisement

<Setting>
Set Pr. 52 and Pr. 158 in accordance with the following table:
Signal Type
Unit
Output
frequency
Output current

Output voltage

Alarm display
Actual
operation time
When 100 is set in Pr. 52, the monitored values during stop and during operation differ
as indicated below:
operation/during stop
Output
frequency
Output current
Output voltage
Alarm display
Note: 1. During an error, the output frequency at error occurrence is displayed.
2. During MRS, the values are the same as during a stop.
During offline auto tuning, the tuning status monitor has priority.
Note: 1. The monitoring of items marked × cannot be selected.
2. By setting "0" in Pr. 52, the monitoring of "output frequency to alarm display"
can be selected in sequence by the
3. Running speed on the PU main monitor is selected by "other monitor
selection" of the parameter unit (FR-PU04).
4. The actual operation time displayed by setting "23" in Pr. 52 is calculated
using the inverter operation time. (Inverter stop time is not included.) Set "0"
in Pr. 171 to clear it.
5. The actual operation time is calculated from 0 to 99990 hours, then cleared,
and recalculated from 0. If the operation time is less than 10 hours there is
no display.
6. The actual operation time is not calculated if the inverter has not operated
for more than 1 hour continuously.
7. When the control panel is used, the display unit is Hz or A only.
Parameter Setting
Pr. 52
Control
panel
LED
Hz
0/100
A
0/100
0/100
0/100
10h
23
0
During
Output frequency
Pr. 158
PU main
AM
monitor
terminal
0/100
0
0/100
1
0/100
2
×
0/100
×
23
Pr. 52
During stop
Set frequency
Output current
Output voltage
Alarm display
key.
SET
90
PARAMETERS
Full-Scale Value of
AM Level Meter
Pr. 55
Pr. 56
400V or 800V


100
During operation
Output frequency

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e 520s ecFr-e 540 ec

Table of Contents