" " Up-to-frequency sensitivity (Pr. 41)

4.2.18 Up-to-frequency sensitivity (Pr. 41)
Pr. 41 "up-to-frequency sensitivity"
The ON range of the up-to-frequency signal (SU) output when the output frequency
reaches the running frequency can be adjusted between 0 and ±100% of the running
frequency.
This parameter can be used to ensure that the running frequency has been reached or
used as the operation start signal etc. for related equipment.
Parameter
Factory
Number
Setting
41
! Use any of Pr. 190 to Pr. 192 to allocate the terminal used for SU signal output.
Refer to page 150 for Pr. 190 to Pr. 192 (output terminal function selection).
Note: When terminal assignment is changed using Pr. 190 to Pr. 192, the other
functions may be affected. Check the functions of the corresponding
terminals before making settings.
Setting
Range
10%
0 to 100%
Related parameters
Pr. 190 "RUN terminal function selection"
Pr. 191 "FU terminal function selection"
Pr. 192 "A, B, C terminal
function selection"
Running frequency
Output signal
SU
OFF
ON
87
PARAMETERS
Adjustable range
Pr.41
Time
OFF