3 Comparison of software functions

FDUL221
FDUL221-EL
FXS2017
__
__
__
__
__
__
__
__
__
Building Technologies
Fire Safety
The table below displays the main differences in terms of functionality for the
following software:
Line tester FDUL221
FDUL221 line tester in 'EL' operation mode
'PC Linetester Tool FXS2017' software
Function and description
Localizing line devices
The internal alarm indicator for the line devices can be activated.
All line devices on
All line devices off
Selected line device on
Line device with error
Line device at the end of a stub line
External AI of the selected line device*
The external alarm indicator of the selected line device is activated automatically.
Summary
List of the types of line devices used.
Overall measurement of the detector line
Resistance measurements for the entire detector line.
Partial measurement of the detector line*
Resistance measurements between start of line and individual line device.
See also chapter 'Error search using the 'measure line device' method [
MC link/FDUD29x support
Information on the individual line device can be displayed on the FDUD29x detector tester (e.g.
the customer text recorded via the 'PC Linetester Tool FXS2017' software or the topology
number). The line device outputs can be activated.
Searching for and configuring the sounder base
The sounder base is configured in such a way that it can subsequently be activated via the
corresponding function in the 'Devices' menu. This configuration is retained and only needs to be
carried out once.
The 'Config Buzzers' command is only required in order to find the sounder base each time the
detector line is read in for existing systems with sounder bases manufactured prior to 2007.
Converting the detector line
Multiple protocol detectors (e.g. FDOOT241-Ax) can be switched to FDnet operation. In order for
this to happen, the detector line is started up repeatedly.
Device status information
Details can be found in the 'The 'device' function [
Controlling switching outputs of the line devices
Details can be found in the 'The 'device' function [
Resetting D-Bus addresses
Set all D-Bus addresses to 0. This function is only required in special cases (e.g. when
commissioning the FDCW221 radio gateway).
Assigning D-Bus addresses
The D-Bus addresses for all line devices are set according to the topology address. This is also
possible with offset.
Saving line topologies
It is possible to save several line topologies in the line tester.
See also chapter 'Saving a line topology [
Comparison of software functions
62]'.
45]' chapter.
45]' chapter.
55]'.
3
15
008250_i_en_--
2013-08-15