Electrically Driven Firewood Processor

In addition to the instructions in this manual on the safe operation and service of a
tractor driven machine, the following points must be observed when operating the
electrically driven machine model TRS 60:
The machine must be placed on a base from which it cannot move or fall during
operation.
The electric motor IP- rating is 55.The fuse rating is min. 16A slow.
The machine is equipped with a male contact. When plugging in the electrical cable,
ensure that:
- the capacity of the cable is high enough;
- the cable and plug are intact;
- the cable is led from the socket to the machine by a route that protects the cord from
damage and ensures it cannot cause damage or injury outsiders;
- when the cable is installed across a passageway, it is dug in the ground and covered
so that the users of the passageway cannot come into contact with the cable;
- the cable is led directly from the plug contact to the contact on the machine (see the
following figure) and never installed on the side where the operator is processing
firewood.
Before starting the machine, make sure that the angular gear cover is in place so
that it is not possible to touch the gear.
The machine must absolutely not be operated if this cover is not in place.
Machine contact
Hakki Pilke 27
14 (39)
Position of the cover when
powered by an electrical
motor