HPOD C-/Ku-Band Outdoor Power Amplifier
Redundancy
Command
Parameter
(Instruction
Type
Code and
Qualifier)
Set Backup
SBO=
Offset
Arguments
for
Description of arguments
Command
(Note that all arguments are ASCII numeric codes,
or
that is, ASCII codes between 48 and 57)
Response
to Query
5 bytes
Command and Query
For 1:2 systems only (Backup unit only):
Sets the offset of the specified unit to be used when
that unit is being backed up
Example: SBO=X,YY.YY
Where:
X = Unit number (1 or 2)
YY.YY = Offset attenuation value
Response to
Command
(Target to controller)
SBO= (message OK)
SBO? (received OK,
but invalid arguments
found)
B–4
Revision 2
MN/HPOD.IOM
Query
Response to
(Instruction
query
Code and
(Target to
qualifier)
controller)
SBO?X
SBO=YY.YY
Where X is
(same format as
the unit
command
number (1 or
arguments)
2)