I N T R O D U C T I O N; Features; Specifications - Paradox Spectra 1759EX V1.0 Reference & Installation Manual

Table of Contents

Advertisement

1 . 1
F E A T U R E S
• Up to 15 fully programmable zones
• Two completely independent partitions. Many of the features and options in the Spectra System can be independently set for each
partition such as event reporting, entry/exit delay, auto-arming and many more. All zones, the keyswitches and all user codes are
assigned to specific partitions, which makes this a true partitioned system.
• Communication bus facilitates the adding, programming and monitoring of all expansion modules.
• 1 Installer Code and 48 User Codes (including: 1 System Master, 2 Masters, and 1 Duress)
• 2 on-board, fully programmable outputs (PGMs) and one 5A alarm relay
• Simple, direct and logical programming
• Event Call Direction: The Spectra 1759EX control panel events are divided into 5 groups of events. Each of these event groups can
be programmed with a separate dialing sequence.
• Two 32-digit Central Station Telephone Numbers and one 32-digit Backup Telephone Number
• Contact ID, Pager Format and many more High-Speed Communication Formats
• "False Alarm Prevention" features such as: Intellizone, Auto Zone Shutdown, Beep on Exit Delay, Programmable Delay Before Alarm
Transmission, and Recent Closing Report
• Regular Arming, Stay Arming, Instant Arming, Force Arming, One-Touch Arming, Auto-Arming, or Keyswitch Arming
• 256 Event Buffer with time stamp
• Telephone Line Supervision
• Keypad activated panic alarms
• Compatible with Winload Security System Management Software for Windows®
1 . 2
S P E C I F I C A T I O N S
1.2.1
S
PECTRA
AC Power:
Battery:
Aux. Power:
Bell Output:
PGM Outputs:
Alarm Relay:
1.2.2
S
PECTRA
Power input:
1 standard keypad zone
On-board tamper switch (optional)
1686H and 1686V 10-Zone LED Keypad
Current consumption:
1689 16-Zone LED Keypad
Current consumption:
1641 32-Character LCD Keypad
Current consumption:
PGM:
LCD:
Specifications may change without prior notice
+
Cannot exceed 200mA for UL installations
++
Cannot exceed 1A for UL installations
P A R T 1 : I N T R O D U C T I O N
1759EX C
P
ONTROL
ANEL
16Vac transformer with minimum 20VA rating (Rec.: 40VA), 50 to 60Hz
12Vdc, 4Ah/7Ah
+
600mA typical, 700mA maximum, fuseless shutdown @ 1.1A
++
1A, fuseless shutdown @ 3A
PGM1 = 150mA low-current output, PGM2 = 2.5A high-current output
One form "C" relay rated @ 125V, 5A receptive load
K
(1686H, 1686V, 1689
EYPADS
Typically 9-16Vdc
62 to 116mA
50 to 117mA
60 to 80mA
1 with 50mA current limit
Super Twisted Nematic display (STN), Wide viewing angle, Backlight & Contrast
adjustable
1641)
AND
3
P E C T R A
S
1 7 5 9 E X

Hide quick links:

Advertisement

Table of Contents
loading