If you notice a gain or loss in control panel time, calculate the average gain or loss per day and program the opposite amount in
order to automatically correct the time setting every 24 hours.
Example: If a control panel loses 4 minutes per month, this represents an average loss of 8 seconds per day. Therefore,
programming 008 (plus 8 seconds) into section [088] would compensate for the 8-second loss.
1 1 . 8 K E Y P A D T A M P E R S U P E R V I S I O N
S e c t i o n [ 1 2 8 ] : G e n e r a l O p t i o n s
O p t i o n
O F F = K e y p a d 1 T a m p e r S u p e r v i s i o n D i s a b l e d ( d e f a u l t )
[ 7 ]
O p t i o n
O N = K e y p a d 1 T a m p e r S u p e r v i s i o n E n a b l e d
[ 7 ]
O p t i o n
O F F = K e y p a d 2 T a m p e r S u p e r v i s i o n D i s a b l e d ( d e f a u l t )
[ 8 ]
O p t i o n
O N = K e y p a d 2 T a m p e r S u p e r v i s i o n E n a b l e d
[ 8 ]
The control panel can be programmed to monitor the on-board tamper status of one or two keypads in the system. If Keypad 1
Tamper Supervision is enabled, the control panel will verify the on-board tamper status of a keypad whose Keypad Zone Jumper
(J1) is set to on. If Keypad 2 Tamper Supervision is enabled, the control panel will verify the on-board tamper status of a keypad
whose Keypad Zone Jumper (J1) is set to off.
Regardless of whether the keypad zones are being used or not, if more than one keypad has the same Keypad
Zone Jumper setting, Keypad Tamper Supervision will be lost. For example, if two of the keypads in your system
have the keypad zone jumper (J1) set to on, the control panel will not recognize a Keypad 1 Tamper Supervision
Failure.
If a keypad tamper occurs, the control panel can transmit the appropriate Zone Tamper report code (see page 34) as originating
from the zones specified by the Table 11. If the zone (as specified by Table 11) is enabled, the control panel will report the tamper
as originating from the partition where the zone is assigned. If the zone is not enabled, the control panel will send the Zone
Tamper report code as originating from partition 1. A Tamper/Zone Wiring Failure will also appear in the keypads' Trouble Display
(see page 47).
When Reassign Keypad Zone 2 is enabled (see section 5.2), the Keypad Tamper Supervision for keypad zone 2 is
lost. Therefore, Keypad Tamper Supervision will
1 1 . 9 K E Y P A D A U D I B L E T R O U B L E W A R N I N G
S e c t i o n [ 1 2 7 ] : G e n e r a l O p t i o n s
O p t i o n
O F F = K e y p a d B e e p o n T r o u b l e D i s a b l e d
[ 3 ]
O p t i o n
O N = K e y p a d B e e p o n T r o u b l e E n a b l e d ( d e f a u l t )
[ 3 ]
When enabled, the keypads emit an intermittent beep tone whenever a trouble condition occurs in the system. The intermittent
beep tone remains activated until the user enters the Trouble Display by pressing the [
will re-initialize whenever a new trouble occurs or the trouble restores and re-occurs.
1 1 . 1 0 C O N F I D E N T I A L M O D E
S e c t i o n [ 1 2 6 ] O p t i o n s [ 1 ] , [ 2 ] a n d [ 3 ]
O p t i o n
O F F = C o n f i d e n t i a l M o d e D i s a b l e d ( d e f a u l t )
[ 1 ]
O p t i o n
O N = C o n f i d e n t i a l M o d e E n a b l e d
[ 1 ]
O p t i o n
O F F = K e y p a d s a c t i v a t e w h e n a n a c c e s s c o d e i s e n t e r e d
[ 2 ]
O p t i o n
O N = K e y p a d s a c t i v a t e w h e n a k e y i s p r e s s e d ( d e f a u l t )
[ 2 ]
O p t i o n
O F F = C o n f i d e n t i a l M o d e T i m e r i s 2 m i n u t e s
[ 3 ]
O p t i o n
O N = C o n f i d e n t i a l M o d e T i m e r i s 5 s e c o n d s ( d e f a u l t )
[ 3 ]
If Confidential Mode is enabled and no actions are performed on the keypads for the time defined by the Confidential Mode
Timer, all the keypads' LEDs will be off and LCD screens will show "Paradox Family" until either a key is pressed or an access
code is entered. When the system exits Confidential Mode, the keypads will display the system's status. Confidential Mode is
activated by enabling option [1]. Option [2] regulates whether the keypads will be activated at the touch of a key or only when an
access code is entered. Option [3] determines the amount of time without action before the system enters Confidential Mode (5
seconds or 2 minutes).
R
& I
4 2
EFERENCE
NSTALLATION
Table 11: Zone Tamper Report Code for Keypad Tamper Supervision Failure
Keypad Tamper
Keypad 1 Tamper Supervision =
Keypad 2 Tamper Supervision =
M
ANUAL
1759EX
Zone 6
Zone 7
function on Keypad Zone 1.
ONLY
] or [
] key. The intermittent beeps
TBL
TRBL