Zone Definitions - Paradox Spectra 1759EX V1.0 Reference & Installation Manual

Table of Contents

Advertisement

Zone Definitions

1 - Entry Delay 1
2 - Entry Delay 2
3 - Follow
4 - Instant
5 - 24Hr. Burglary
6 - 24Hr. Buzzer
Additional definitions for
on-board terminals:
7 - Keyswitch
8 - 24Hr. Fire
9 - 24Hr. Delayed Fire
5 . 5
Z O N E D E F I N I T I O N S
As demonstrated in Figure 5.1, sections [001] to [015] represent zones 1 through 15 respectively, where the first digit in each of
these sections represents the zone's definition. Also, refer to Zone Speed on page 22. To disable a zone, clear the contents of
the section corresponding to the desired zone by pressing the [
Zone Definitions, which are described as follows.
5.5.1
E
NTRY
S e c t i o n s [ 0 0 1 ] t o [ 0 1 5 ] : Z o n e s 1 t o 1 5 , F i r s t D i g i t =
When the system is armed and a zone defined with Entry Delay 1 opens, the control panel will generate an alarm after
the programmed Entry Delay 1 Timer elapses. This is to provide users with enough time to enter the protected area
and disarm the system. To program the Entry Delay 1 Timer, key in the desired 3-digit delay value (000 to 255
seconds, Default = 45 seconds) into section [069]. Entry Delay zones are commonly used at the entry/exit points of the
protected area (i.e. front/back door, garage, etc.). Using different Entry Delays (see Entry Delay 2) is useful when, for
example, one entry point requires a longer delay than the other entry point or in a partitioned system where each
partition may require a different Entry Delay.
5.5.2
E
NTRY
S e c t i o n s [ 0 0 1 ] t o [ 0 1 5 ] : Z o n e s 1 t o 1 5 , F i r s t D i g i t =
Entry Delay 2 zones are identical to the Entry Delay 1 zones (see section 5.5.1), except it uses a separate Entry Delay
Timer. To program the Entry Delay 2 Timer, key in the desired 3-digit delay value (000 to 255 seconds, Default = 45
seconds) into section [070].
R
& I
1 8
EFERENCE
NSTALLATION
Figure 5.1: Spectra Zone Programming
Select
one
D
1
ELAY
D
2
ELAY
This timer is also used as the Stay Delay timer (see section 7.2).
M
ANUAL
Press the
[
] key
ENTER
Enter the
[
]
INSTALLER CODE
Key in 3-digit
[
]
SECTION
Zone Definition
First Digit
Zone Partition
Assignment
Second Digit
Keypads beep twice
Zone Options
Feature Select
Press [
]
ENTER
] key 3 times and pressing [
FORCE
1
2
[001] = Zone 1
[002] = Zone 2
[003] = Zone 3
[004] = Zone 4
[005] = Zone 5
[006] = Zone 6
[007] = Zone 7
[008] = Zone 8
Zone Partition Assignment
1 - Zone Assigned to Partition 1
2 - Zone Assigned to Partition 2
3 - Zone Assigned to both Partitions
Select
one
Zone Options
[1] Auto Zone Shutdown Enabled
[2] Bypass Enabled
[3] Stay Zone
[4]
[5]
Zone Alarm Type
OFF OFF Audible Alarm (steady)
OFF ON
Audible Alarm (pulsed)
ON
OFF Silent Alarm
ON
ON
Generates only a report
[6] Intellizone
[7] Delay alarm transmission
[8] Force Zone
Keyswitch Options
[1]
OFF= Maintained
ON = Momentary
[2]
OFF = Regular Arm
ON = Stay Arm
ENTER
[009] = Zone 9
[010] = Zone 10
[011] = Zone 11
[012] = Zone 12
[013] = Zone 13
[014] = Zone 14
[015] = Zone 15