Switch To Stay Arming; Stay Arming With Delay; Regular Arming Switches To Force Arming; Restrict Arming On Battery Fail - Paradox Spectra 1759EX V1.0 Reference & Installation Manual

Table of Contents

Advertisement

P A R T 7 : A R M I N G A N D D I S A R M I N G O P T I O N S
7 . 1
S W I T C H T O S T A Y A R M I N G
S e c t i o n [ 1 3 3 ] = P a r t i t i o n 1 , S e c t i o n [ 1 3 4 ] = P a r t i t i o n 2
O p t i o n
O F F = S w i t c h t o S t a y A r m i n g D i s a b l e d ( d e f a u l t )
[ 4 ]
O p t i o n
O N = S w i t c h t o S t a y A r m i n g E n a b l e d
[ 4 ]
If a user Regular arms a partition, but does not exit through (open and close) an Entry Delay zone during the Exit Delay, the
control panel can be programmed to switch from Regular Arming to Stay Arming.
7 . 2
S T A Y A R M I N G W I T H D E L A Y
S e c t i o n [ 1 3 3 ] = P a r t i t i o n 1 , S e c t i o n [ 1 3 4 ] = P a r t i t i o n 2
O p t i o n
O F F = S t a y A r m i n g w i t h D e l a y D i s a b l e d ( d e f a u l t )
[ 5 ]
O p t i o n
O N = S t a y A r m i n g w i t h D e l a y E n a b l e d
[ 5 ]
When a partition is Stay Armed when this feature is enabled, all the zones in the partition, except 24Hr. zones, are associated
with the Stay Delay. Therefore, the control panel will not generate an alarm if a zone is breached until the Stay Delay has elapsed.
This feature prevents false alarms by allowing users enough time to disarm their system if a zone is accidentally triggered. For
example, if a user opens an armed window or crosses an armed detector on the way to the kitchen in the middle of the night, the
user will have enough time to disarm the system before the alarm is generated. Each partition's Stay Delay follows the value
programmed in Entry Delay Timer 2 in section [070].
7 . 3
R E G U L A R A R M I N G S W I T C H E S T O F O R C E A R M I N G
S e c t i o n [ 1 3 1 ] : A r m i n g / D i s a r m i n g O p t i o n s
O p t i o n
O F F = R e g u l a r A r m i n g S w i t c h e s t o F o r c e A r m i n g D i s a b l e d ( d e f a u l t )
[ 2 ]
O p t i o n
O N = R e g u l a r A r m i n g S w i t c h e s t o F o r c e A r m i n g E n a b l e d
[ 2 ]
With this feature enabled, the control panel will always Force arm instead of Regular arm when a valid User Access Code with
the Force Arming Option is entered. In installations where the user must always Force arm when leaving the protected area, this
feature allows users to Force arm without pressing the [
7 . 4
R E S T R I C T A R M I N G O N B A T T E R Y F A I L
S e c t i o n [ 1 3 0 ] : A r m i n g / D i s a r m i n g O p t i o n s
O p t i o n
O F F = P e r m i t a r m i n g o n b a t t e r y f a i l u r e ( d e f a u l t )
[ 5 ]
O p t i o n
O N = R e s t r i c t a r m i n g o n b a t t e r y f a i l u r e
[ 5 ]
If this option is enabled, the control panel will not arm the system if the control panel detects that the backup battery is
disconnected, that its fuse is blown, or that the battery voltage drops to less than 10.5V. The control panel will not arm the system
until all battery trouble conditions are rectified.
7 . 5
R E S T R I C T A R M I N G O N T A M P E R F A I L U R E
S e c t i o n [ 1 3 0 ] : A r m i n g / D i s a r m i n g O p t i o n s
O p t i o n
O F F = P e r m i t a r m i n g o n t a m p e r f a i l u r e ( d e f a u l t )
[ 6 ]
O p t i o n
O N = R e s t r i c t a r m i n g o n t a m p e r f a i l u r e
[ 6 ]
If this option is enabled, the control panel will not arm the system if the control panel detects a tamper trouble on one or more
zones. The control panel will not arm the system until all tamper trouble conditions are rectified.
This feature will not function if the Tamper Recognition Options (see page 30) are disabled or whenever the
tampered zone is bypassed and the Tamper Bypass Options (see page 30) have been enabled.
7 . 6
T I M E D A U T O - A R M I N G
S e c t i o n [ 1 3 3 ] = P a r t i t i o n 1 , [ 1 3 4 ] = P a r t i t i o n 2
O p t i o n
O F F = T i m e d A u t o - A r m i n g D i s a b l e d ( d e f a u l t )
[ 1 ]
O p t i o n
O N = T i m e d A u t o - A r m i n g E n a b l e d
[ 1 ]
Each partition can be programmed to arm every day at the time specified by the Auto-Arm Timer. The Auto-Arming Options (see
section 7.8) determine the partition's arming method. Any open zones detected when a partition is Auto-Armed will be bypassed
regardless of their definition (except 24hr. zones). The control panel will enter a 60-second Exit Delay period before arming the
system. At this point, Auto-Arming can be cancelled by entering a valid access code. Once the partition has successfully armed,
the control panel can transmit the Timed Auto-Arming report code programmed in section [172].
Example: To automatically arm partition 2 everyday at 6:15PM, enable Timed Auto-Arming for partition 2 by turning on option [1]
in section [134]. Then key in 18:15 into section [112].
( N O T T O B E U S E D W I T H U L I N S T A L L A T I O N S )
] key before entering their User Access Code.
FORCE
2 7
P E C T R A
S
1 7 5 9 E X