Figure 5.2: Bell Output During Fire Alarm
5 . 7
Z O N E P A R T I T I O N A S S I G N M E N T
S e c t i o n s [ 0 0 1 ] t o [ 0 1 5 ] : Z o n e s 1 t o 1 5
The control panel provides the option of partitioning the security system
into two completely independent systems. As demonstrated in Figure 5-1
on page 18, sections [001] to [015] represent zones 1 through 15
respectively, where the second digit in each of these sections represents
the zone's partition assignment. The zone is assigned to Partition 1 if
second digit = 1, Partition 2 if second digit = 2, or both partitions is
second digit = 3. For details on Partitioning, refer to page 41.
5 . 8
Z O N E O P T I O N S
As demonstrated in Figure 5.1, sections [001] to [015] represent zones 1
through 15 respectively. After entering the first two digits, select one or
more of the following Zone Options by using the Multiple Feature Select
Programming Method (see page 11):
5.8.1
A
UTO
S e c t i o n s [ 0 0 1 ] t o [ 0 1 5 ] = Z o n e s 1 t o 1 5
O p t i o n
O p t i o n
If, in a single armed period, the number of alarms generated by
a zone with the Auto Zone Shutdown option enabled exceeds
the number defined by the Auto Zone Shutdown Counter, the
control panel will no longer generate an alarm for that zone. To
program the Auto Zone Shutdown Counter, key in the desired
limit (000=Disabled, 001 to 015, Default = 5) into section [089].
The Auto Zone Shutdown Counter resets every time the
system is armed.
5.8.2
B
YPASS
S e c t i o n s [ 0 0 1 ] t o [ 0 1 5 ] = Z o n e s 1 t o 1 5
O p t i o n
O p t i o n
When a user, utilizes the Bypass Programming feature (see page 49), only zones with the Bypass option enabled can
be programmed as bypassed.
5.8.3
S
Z
TAY
S e c t i o n s [ 0 0 1 ] t o [ 0 1 5 ] : Z o n e s 1 t o 1 5
O p t i o n
O p t i o n
Zones with the Stay option enabled will be bypassed when the system is Stay Armed (see page 49).
5.8.4
A
LARM
S e c t i o n s [ 0 0 1 ] t o [ 0 1 5 ] : Z o n e s 1 t o 1 5
[4] OFF / [5] OFF: Audible Steady (default)
When the conditions for an alarm have been met, the control panel can transmit the appropriate Zone Alarm report
code (see page 33) and provides a steady output for any bells or sirens connected to the control panel's bell output.
R
& I
2 0
EFERENCE
NSTALLATION
Z
S
ONE
HUTDOWN
O F F = A u t o Z o n e S h u t d o w n D i s a b l e d
[ 1 ]
O N
= A u t o Z o n e S h u t d o w n E n a b l e d f o r
[ 1 ]
s e l e c t e d z o n e ( d e f a u l t )
Z
ONES
O F F = B y p a s s Z o n e D i s a b l e d
[ 2 ]
O N
= S e l e c t e d Z o n e i s B y p a s s E n a b l e d ( d e f a u l t )
[ 2 ]
Do not program a Fire Zone with the Bypass option, as the control panel will never bypass Fire Zones.
ONES
O F F = S t a y Z o n e D i s a b l e d ( d e f a u l t )
[ 3 ]
O N
= S e l e c t e d Z o n e i s S t a y E n a b l e d
[ 3 ]
Do not program a Fire Zone with the Stay option, as the control panel will never bypass Fire Zones
when Stay Arming.
T
YPES
M
ANUAL
Figure 5.3: Delayed 24Hr. Fire Zone