Element QA
WiFly On/Off and Wireless Addressing:
This function is used to activate the WiFly control and set the WiFly
address.
NOTE: The address must match the address that is set to WiFly
TransCeiver or WiFly controller.
1. Plug the fixture in and press the MODE button until "rCXX" is
displayed. You are in wireless set up mode.
2. Press the UP or DOWN buttons the UP or DOWN buttons to turn
the Wireless "On" or "Off".
3. Press the SET UP button to enter the Wireless address menu. Use
the UP or DOWN buttons to select your desired Wireless address.
Activate IR Sensor:
This function is used to activate and deactivate the IR sensor. When
this function is activated you can control the fixture using the UC IR or
Airstream IR App. Please see page 33 for controls and functions.
1. Plug the fixture in and press the MODE button until "dXX" is dis-
played. "XX" represents either "on" or "oFF".
2. Press the SET UP button until "IrXX" is displayed. "XX" represents
either "on" or "oF".
3. Press the UP or DOWN buttons to either activate the remote func-
tion (On) or deactivate it (Off).
Slave Setting:
1. Plug the fixture in and press the MODE button until "SLAv" is
displayed. The unit now designate a "Slave" unit in a Master-Slave
set up.
Default Running Mode:
This is a default running mode. When this mode is activated all modes
will return to their default settings.
1. Plug the fixture in and press the MODE button until "dXX" is dis-
played. "XX" represents either "on" or "oFF".
2. Press the SET UP button until "dEFA" is displayed.
3. Press the UP and DOWN buttons simultaneously. Press the
MODE button to exit.
ADJ Products, LLC - www.adj.com - Element QA User Manual Page 30
Operating Instructions
Element QA
Master-Slave Configuration:
This function will allows you to link units together to run in a Master-
Slave set up. In a Master-Slave set up one unit will act as the control-
ling unit and the others will react to the controlling units built-in pro-
grams. Any unit can act as a Master or as a Slave however, only one
unit can be programmed to act as the "Master."
Master-Slave Connections and Settings:
1. Daisy chain your units via the XLR connector on the rear of
the unit. Use standard XLR data cables to link your units together.
Remember that the Male XLR connector is the input and the
Female XLR connector is the ouput. The first unit in the chain
(master) will use the female XLR connector only. The last unit in
the chain will use the male XLR connector only.
2. Set the "Master" unit to your desired operating mode and then
connect the "Slave" unit or units.
3. For the "Slave" unit(s) press the MODE button until "SLAu" is dis-
played. The "Slave" unit(s) will now follow the "Master" unit.