Advertisement

ENCORE BURST RGBW IP
User Instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ENCORE BURST RGBW IP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ADJ ENCORE BURST RGBW IP

  • Page 1 ENCORE BURST RGBW IP User Instructions...
  • Page 2 All non-ADJ Products, LLC brands and product names are trademarks or registered trademarks of their respective companies. ADJ Products, LLC and all affiliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic...
  • Page 3: Table Of Contents

    DMX Addressing DMX Modes System Menu Multiple Unit Power Linking I Dimmer Curve Chart Dimensional Drawing I Trouble Shooting I Cleaning Limited Warranty (USA Only) Specifications ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 2...
  • Page 4: Introduction

    Do not return this unit to your dealer without first contacting customer support. Introduction: The ADJ Encore Burst RGBW IP is a DMX intelligent, high powered LED fixture. To optimize the performance of this product, please read these operating instructions carefully to familiarize yourself with the basic operations of this unit.
  • Page 5: Features I Warranty Registration

    Encore Burst RGBW IP Warranty Registration The Encore Burst RGBW IP carries a 2 year limited warranty. Please fill out the enclosed warranty card to validate your purchase. All returned service items whether under warranty or not, must be freight pre-paid and accompany a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package.
  • Page 6: Safety Guidelines

    • The fixture should be serviced by qualified service personnel when the appliance does not appear to operate normally or exhibits a marked change in performance. ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 5...
  • Page 7: Ip65 Notice

    Damages and/or performance issues resulting from installation in a marine and/or coastal environment will void the manufactures warranty and will NOT be subject to any warranty claims and/or repairs. ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 6...
  • Page 8: Overview

    Mode Button Up Button Down Button Enter Button IP65 5-Pin DMX In IP65 5-Pin DMX Out IP65 Power In IP65 Power Out Safety Cable Rigging Point ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 7...
  • Page 9: Installation

    The Encore Burst RGBW IP is fully operational in three different mounting positions; hanging upside- down, mounted sideways on trussing, or set on a flat level surface. Be sure this fixture is kept at least 12m (40ft) away from any flammable materials (decoration etc.).
  • Page 10: Connections

    TO MAINTAIN IP65 RATING INTEGRITY AND PREVENT WATER FROM ENTERING THE FIXTURE, ALL UNUSED CONNECTION RUBBER CAPS MUST BE SEALED. ONLY IP65 RATED POWER AND DATE CABLES MUST BE USED. ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 9...
  • Page 11: Dmx Set Up

    2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ part number Z-DMX/T) will decrease the possibilities of erratic behavior.
  • Page 12: Dmx Addressing

    In the case of the Encore Burst RGBW IP , when in 4 channel mode you should set the starting DMX address of the first unit to 1, the second unit to 5 (4 + 1), the third unit to 9 (5 + 4), and so on. (See chart below for more details.)
  • Page 13: Dmx Modes

    Lime Green 196-202 Spring Yellow 203-210 Deep Amber 211-217 Chrome Orange 218-225 Orange 226-232 Gold Amber 233-240 Millennium Gold 241-247 Deep Gold Amber 248-255 Flame Red ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 12...
  • Page 14 DIMMER DELAY TIME 0.1Sec. 0.2Sec. 0.3Sec. 0.4Sec. 0.5Sec. 0.6Sec. 0.7Sec. 0.8Sec. 0.9Sec. 1.0Sec. 1.5Sec. 2.0Sec. 3.0Sec. 4.0Sec. 5.0Sec. 6.0Sec. 7.0Sec. 8.0Sec. 9.0Sec. 10Sec. 141-255 Default to Unit Setting ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 13...
  • Page 15 5000HZ 166-180 6000HZ 181-195 10000HZ 196-210 15000HZ 211-225 20000HZ 226-255 25000HZ GAMMA 000-020 Default to Unit Setting 021-040 041-060 061-080 081-100 101-120 121-130 131-255 No Function ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 14...
  • Page 16: System Menu

    MENU button.If there are no changes/ adjustments made within 10 seconds, the unit will revert back to the setting made under “No DMX State”. MENU ENTER ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 15...
  • Page 17 (2) Maximum Temperature - Overall maximum fixture temp. that has been recorded. (Not Resettable) (3) DMX value options depend on the DMX Channel mode the fixture is set to. ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 16...
  • Page 18 This time CAN be reset. NOTE: The displayed time represents the current power ON time since the last reset. • P-On Time-Reset - Reset the CURRENT power ON running time that is displayed under “P-On Time-R”. ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 17...
  • Page 19 DMX VALUES - Displays the DMX values of any DMX channel that is currently in use. NOTE: DMX value options depend on the current DMX channel mode setting. SOFTWARE VERSION - The current software version is displayed. ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 18...
  • Page 20: Multiple Unit Power Linking I Dimmer Curve Chart

    Down Time (ms) Standard (default) Stage 1100 1540 1660 1180 1520 1860 1940 Architectural 1380 1730 2040 2120 Theatre 1580 1940 2230 2280 1100 1660 Stage 2 ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 19...
  • Page 21: Dimensional Drawing I Trouble Shooting I Cleaning

    2. Clean the external optics with glass cleaner and a soft cloth every 20 days. Cleaning frequency depends on the environment in which the fixture operates (i.e. smoke, fog residue, dust, dew). ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 20...
  • Page 22: Limited Warranty (Usa Only)

    ADJ Products, LLC concludes, after inspection, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the ADJ Products, LLC factory unless prior written authorization was issued to purchaser by ADJ Products, LLC; if the product is damaged because not properly maintained as set forth in the instruction manual.
  • Page 23: Specifications

    5 DMX Modes: 4 / 6 / 7 / 8 / 11 Warranty: 2 Year (730 days) Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without notice. ADJ Products, LLC - www.adj.com - Encore Burst RGBW IP User Manual Page 22...

Table of Contents