Ablerex ARES RT-1K User Manual page 21

Intelligent true on-line ups for corporate and it users
Table of Contents

Advertisement

Line mode
(Rating 230Vac)
Efficiency
Battery mode
(12Vdc/pcs)
( Full Linear Load )
ECO mode
(Rating 230Vac)
Number of batteries
Battery type
Battery
(Sealed, non-
Rated Battery Voltage
spillage,
50% Load
Backup
maintenance-
time
free, lead acid)
70% Load
(Linear
Load)
100%Load
Charge
Current
Standard
(Max.)
Supplem
entary
(Optional)
Charger
(Max.)
Charger
Recharge
time
(to
90%)
Floating Mode
Charging Voltage
Bluk Mode Charging
Voltage
DC leakage current
AC to DC
Transfer time
Inverter to Bypass
DC start
Self Diagnostics
LCD (Standard)
Front Panel
LED (Optional)
Bypass Mode :
1 05
continuous
106-120
for 250 seconds shuts down
121-130
for 125 seconds shuts down
131-135
for 50 seconds shuts down
136-145
for 20 seconds shuts down
146-148
for 5 seconds shuts down
149-157
for 2 seconds shuts down
158-176
for 1 seconds shuts down
177-187
for 0.32 seconds shuts down
1 88
f or 0.16 seconds shuts down.
Buzzer continuously alarms.
90%
91%
86%
87%
97%
97%
3
6
12 V/ 7.2 Ah
36 VDC
72 VDC
>11 min
>11 min
>8 min
>8 min
> 4 min
> 4 min
2.1A
1.5A
3.1A
3.1A
4hr
4hr
40.95Vdc ±1
81.9Vdc±1
42.3Vdc±1
84.6Vdc±1
≤ 30 µA with no AC applied and the unit in the off position
0 ms
4ms(Typical) / 0ms(Optional)
4ms(Typical)
Yes
Upon Power-on, Front Panel Setting & Software Control, 24
hours routine check
Normal, Battery, Bypass, Self-Test, Battery Weak & Bad,
Site Wiring Fault , Fault, Overload, and Load/Battery Level
(Optional)
P rogrammable Outlet1/ Programmable Outlet2
40
Audible Alarm
Protection
91%
87%
97%
Physical
6
12 V/ 9 Ah
72 VDC
>9 min
Environmental
> 6 min
> 3 min
1.5A
Interface
3.1A
Standards and
4hr
Certifications
81.9Vdc
1
±
* The UPS Communication software may be downloaded form Ablerex Web-site at:
84.6Vdc±1
http://www.ablerex.com.tw/tw/htm/support-sl.htm
4 Button(Optional)
ON / OFF / Select / Silence
6 Button(Standard)
ON(Silence) / OFF / Enter / Function / UP / Down
Battery Mode
Sounds once every 1.5 seconds
Low Battery
Sounds once every 0.2 seconds
Overload
Sounds once every 3 seconds
Normal alarm
Sounds once every 3 seconds
Fault
Bypass mode : Circuit Breaker
Normal Mode : Output Breaker/Electronic Circuit
Short Circuit
Battery Mode : Output Breaker/Electronic Circuit
Battery
EPO
UPS shuts down immediately.
Normal Mode :Transfer to Bypass Mode
Over Temperature
Battery Mode : UPS shuts down immediately.
DimensionsUPS (inches)
17.3 x 3.5(2U) x 15.9
W x H x D( mm)
(440 x 88 x 405)
Weightlbs.(kg)
25.8 lb ( 11.7kg )
Operating : 0ºC ~ 40ºC(32ºFto104ºF)
Operating
Temperature
Storage : -10ºC ~ 50ºC(14ºFto122ºF)
Noise Level
Relative Humidity
0-90% (without condensation)
Standard
2nd RS232, USB, RS485, Dry Contact Relay, SNMP/WEB
Option
Compatible Platforms
Microsoft Windows series, Linux, Mac, etc.
Safety
EMC
EN62040-2, EN61000-3-2, EN61000-3-3
Markings
41
Continuous tone
ABDM
17.3 x 3.5(2U) x 23.6
17.3 x 3.5(2U) x 23.6
(440 x 88 x 600)
(440 x 88 x 600)
48.0 lb ( 21.8kg )
54.2 lb ( 24.6kg )
5 0dB
EPO/ROO,RS-232
Card
IEC/EN 62040-1
CE

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ares rt-2kAres rt-3k