Ablerex JP-PRO XL 1000 User Manual

Tower and rack-mount convertible ups

Advertisement

Tower and Rack-Mount
Convertible UPS
User's Manual
1000/1500/2000/3000

Table of Contents

1
Introduction ------------------------------------------------------------------------------------2
2
IMPORTANT SAFETY INSTRUCTION -------------------------------------------------3
2.1
An Important Notice ------------------------------------------------------------3
2.2
Storage Instruction --------------------------------------------------------------4
3
SET UP -----------------------------------------------------------------------------------------5
3.1
Inspection ------------------------------------------------------------------------5
3.2
Place the UPS Properly---------------------------------------------------------5
3.3
Unpacking------------------------------------------------------------------------6
3.4
Selecting Installation Position -------------------------------------------------7
3.5
UPS Setup------------------------------------------------------------------------7
3.6
Tower Setup ---------------------------------------------------------------------8
3.7
Rack-Mount Setup --------------------------------------------------------------9
3.8
UPS Front Panel--------------------------------------------------------------- 11
3.9
LCD Display Panel ----------------------------------------------------------- 12
3.10
UPS Real Panel---------------------------------------------------------------- 13
4
INSTALLATION --------------------------------------------------------------------------- 16
4.1
Connect Utility and Load ---------------------------------------------------- 16
4.2
Connect Network Surge protection ----------------------------------------- 17
4.3
Connect Computer Interface Port ------------------------------------------- 17
4.4
Use with Extended Battery Bank ------------------------------------------- 18
4.5
Installation the UPS with Battery Bank ------------------------------------ 18
4.6
Connect Extended Battery Bank to UPS ----------------------------------- 19
5
OPERATION -------------------------------------------------------------------------------- 20
5.1
Turn on the UPS -------------------------------------------------------------- 20
5.2
Turn Off the UPS ------------------------------------------------------------- 20
5.3
Plug-in Charge ---------------------------------------------------------------- 20
5.4
Auto-Restart ------------------------------------------------------------------- 21
5.5
Alarm Silence------------------------------------------------------------------ 21
5.6
Self Test ------------------------------------------------------------------------ 21
6
UPS MAINTENANCE --------------------------------------------------------------------- 23
6.1
Battery Replacement---------------------------------------------------------- 23
6.2
How to Replace Battery ------------------------------------------------------ 24
6.3
Recycling the Used battery -------------------------------------------------- 25
7
SPECIFICATIONS ------------------------------------------------------------------------- 26
1

Advertisement

Table of Contents
loading

Summary of Contents for Ablerex JP-PRO XL 1000

  • Page 1: Table Of Contents

    Table of Contents Introduction ------------------------------------------------------------------------------------2 IMPORTANT SAFETY INSTRUCTION -------------------------------------------------3 An Important Notice ------------------------------------------------------------3 Storage Instruction --------------------------------------------------------------4 SET UP -----------------------------------------------------------------------------------------5 Inspection ------------------------------------------------------------------------5 Place the UPS Properly---------------------------------------------------------5 Unpacking------------------------------------------------------------------------6 Selecting Installation Position -------------------------------------------------7 UPS Setup------------------------------------------------------------------------7 Tower Setup ---------------------------------------------------------------------8 □ Rack-Mount Setup --------------------------------------------------------------9 UPS Front Panel--------------------------------------------------------------- 11 LCD Display Panel ----------------------------------------------------------- 12 3.10 UPS Real Panel---------------------------------------------------------------- 13...
  • Page 2: Introduction

    1 Introduction 2 IMPORTANT SAFETY INSTRUCTION The UPS featured with Tower/Rack Convertible design, Double AVR Boost and An Important Notice Double Buck, Pure Sine Wave Output, User’s Friendly LCD Display, Built-in customer Option Slot, Hot Swappable Battery, and USB/RS232 Communication interface, provides 1.
  • Page 3: Storage Instruction

    15.This UPS supports electronic equipment in offices, telecommunications, process 3 SET UP control, medical and security applications. Non-authorized technician is not allowed to install the UPS in the following areas: Inspection a. Medical equipment directly related to human life b. Elevator, Metro (Subway) system or any other equipment related to human Inspect the UPS upon receipt.
  • Page 4: Unpacking

    Selecting Installation Position Unpacking It is necessary to select a proper environment to install the unit, in order to 1. Take the UPS out of the PE foam. minimize the possibility of damage to the UPS and extend the life of the UPS. Please follow the instructions below: 2.
  • Page 5: Tower Setup

    Tower Setup 3.7 Rack-Mount Setup Stand alone unit Step1 Step1 Step2 Step2...
  • Page 6: Ups Front Panel

    Step3 UPS Front Panel Step4 Step5...
  • Page 7: Lcd Display Panel

    LCD Display Panel 3.10 UPS Real Panel 1000 / 1500VA 110/115/120V Rear Panel 1. Utility LED 2. Fault LED 3. On Switch 4. Off Switch 5. Battery Replacement LED 6. Battery Backup LED 7. Screw for Easy Swappable Battery Cover 220/230/240V Rear Panel 8.
  • Page 8 2000VA 3000VA 110/115/120V Rear Panel 110/115/120V Rear Panel 220/230/240V Rear Panel 220/230/240V Rear Panel 1. RJ45 Port 2. DIP Switch 1. RJ45 Port 3. USB Communication Port 2. DIP Switch 4. RS232 Communication Port 3. USB Communication Port 5. Output Breaker 4.
  • Page 9: Installation

    4 INSTALLATION Connect Network Surge protection Connect Utility and Load Connect a 10 base-T / 100 base-T network cable with the RJ-45 network surge protection “IN” jack on the rear of the UPS. Connect from the “OUT” jack with network cabling to network equipment. First, connect the UPS with Utility, then plug the loads into the Outlets on the rear of the UPS.
  • Page 10: Use With Extended Battery Bank

    4.4 Use with Extended Battery Bank Step2 Caution--- Battery bank connectors are color coded as show below. Do not try to install battery bank with connectors that are a different color from the battery bank connector in the UPS. Nominal System UPS model Voltage Battery Bank model...
  • Page 11: Operation

    5 OPERATION You have to charge for at least 8 hours every 3 months to avoid from battery self over-discharge naturally, if the UPS is in an idle condition. Turn on the UPS 1. Connect the UPS to the wall receptacle. LCD will display “OFF”, when Auto-Restart Utility is normal.
  • Page 12: Ups Maintenance

    6 UPS MAINTENANCE Storage --- Battery Replacement Store at -15 to +30 °C (+5 to +86 °F), charge the UPS battery every six months. When the UPS is started up or a self-test is executed, the Battery Store at +30 to +45 °C (+86 to +113 °F), charge the UPS battery every three Replacement LED might light up due to battery weak or battery dead.
  • Page 13: How To Replace Battery

    STEP 3 How to Replace Battery STEP 1 Recycling the Used battery Contact your local recycling or hazardous waste center for information on proper disposal of the used battery. STEP 2...
  • Page 14: Specifications

    7 SPECIFICATIONS Power Ranting Model Voltage Power Level Input Voltage Range 1000VA 110/115/120 1000VA/600W 220/230/240 1500VA 110/115/120 1500VA/900W 220/230/240 -32% to +35% of nominal 2000VA Voltage 110/115/120 2000VA/1200W 220/230/240 3000VA 110/115/120 3000VA/1800W 220/230/240 Technical specification Frequency 45-65Hz± 0.5Hz, Auto Sensing (Normal mode) Range 50/60Hz±...

This manual is also suitable for:

Jp-pro xl 1500Jp-pro xl 2000Jp-pro xl 3000

Table of Contents