T05-05 Configuring RAID 0 Properties by Using the Hard Disk Controller
LSI SAS2208
T05-0501 Configuring RAID 0 Properties by Using the Hard Disk Controller LSI SAS2208
Objective
Test Networking
Diagram
Preset Conditions
Test Procedures
Expected Result
Test Description
T05-06 Setting and Verifying a Global Hot Spare Disk by Using the Hard
Disk Controller LSI SAS2208
T05-0601 Setting and Verifying a Global Hot Spare Disk by Using the Hard Disk
Controller LSI SAS2208
Objective
Test Networking
To verify that you can configure RAID 0 properties by using the hard disk controller
SAS2208
None
The server is powered on, and the hard disks are detected.
1.
Press Ctrl+H in the POST phase. The window for configuring the LSI SAS2208
is displayed.
2.
Click Configuration Wizard.
3.
In the displayed window, select New Configuration and click Next.
4.
Click Yes when "You have chosen to clear the configuration. This will destroy
all virtual drives. All data on all virtual will be lost. Are you sure you want to clear
the configuration?" is displayed. In the displayed window, select Manual
Configuration and click Next.
5.
In the Drives pane, select all the hard disks while holding down Ctrl. Click Add
to Array to add the hard disks to Drive Groups on the right. Click Accept DG
and Next.
6.
In the displayed window, click Add to SPAN in the Array with Free Space
pane. Click Next after the disk group is added to SPAN. In the Virtual Drive
Definition window, select RAID 0, enter the recommended capacity (under
Virtual Drives) in Select Size, and retain default settings for other parameters.
Then click Accept. Click Yes when "Write Through mode eliminates risk of
losing cached data in case of power failure. But it may result in slower
performance. Are you sure you want to select write through mode?" is
displayed.
7.
Click Next and Accept in the two displayed windows respectively.
8.
Click Yes when "Save this configuration?" is displayed.
9.
Select Yes when "All data on the new Virtual Drives will be lost, want to
initialize?" is displayed.
10.
Click Home. Spanned Drive Group: 0, RAID 0 is displayed under Logical
View on the right, RAID 0 properties are configured successfully.
RAID 0 properties are configured successfully.
To verify that you can set a global hot spare disk by using the LSI SAS2208
None