T05-08 Verifying the RAID State Migration Function for the Hard Disk
Controller LSI SAS2308
T05-0801 Verifying the RAID State Migration Function for the Hard Disk Controller
LSI SAS2308
Objective
Test Networking
Diagram
Preset Conditions
Test Procedures
Expected Result
Test Description
T05-09 Verifying the RAID State Migration Function for the Hard Disk
Controller LSI SAS2208
T05-0901 Verifying the RAID State Migration Function for the Hard Disk Controller
LSI SAS2208
Objective
Test Networking
Diagram
Preset Conditions
Test Procedures
To verify the RAID state migration function for the LSI SAS2308
None
Two servers are available and powered on, and the hard disks are detected.
1.
Press Ctrl+C in the POST phase. The screen for configuring the LSI SAS2308
properties is displayed.
2.
Select two hard disks, and configure RAID 1 properties for the hard disks. For
details, see case T05-01.
3.
Power off the server, and remove the power cables.
4.
Remove the two RAID 1 member disks from the server in step 2, and install
them on another server that has the same configurations as the previous one.
For details about how to verify RAID properties, see case T01-0501.
5.
Power on the latter server in step 4. Press Ctrl+C in the POST phase. The
screen for configuring the LSI SAS2308 is displayed.
6.
Select LSISAS2308 and press Enter.
7.
Select RAID Properties and press Enter.
8.
Select Manage Array and press Enter. Then select Activate Array on the
displayed screen.
RAID 1 properties are successfully activated on the new server.
This case uses RAID 1 properties supported by the LSI2308 as an example.
To verify the RAID state migration function for the LSI SAS2208
None
Two servers are available and powered on, and the hard disks are detected.
1.
Press Ctrl+H in the POST phase. The window for configuring the LSI SAS2208
is displayed.
2.
Select all the hard disks, and configure RAID 5 properties for the hard disks.
For details, see case T05-03.