Keithley 2601 User Manual page 18

Series 2600 system sourcemeter instruments
Hide thumbs Also See for 2601:
Table of Contents

Advertisement

Section 1: Front and Rear Panel Operation
2. Source-measure setup, performance control and special operation:
Top Row – Source-measure setup
Model 2601/2611/2635 and Model 2602/2612/2636:
SRC
MEAS
LIMIT
MODE
Model 2602/2612/2636 only:
SRC
MEAS
LIMIT
MODE
Middle Row – Source-measure setup
Model 2601/2611/2635 and Model 2602/2612/2636:
DIGITS
SPEED
REL
FILTER
Model 2602/2612/2636 only:
DIGITS
SPEED
REL
FILTER
Bottom Row – Source-measure setup
LOAD
RUN
STORE
RECALL
TRIG
MENU
EXIT
ENTER
1-4
Channel A – Selects the source function (V or A) and places cursor in the source field
for editing.
Channel A – Cycles through measure functions (V, A, Ω or W).
Channel A – Places the cursor in the compliance limit field for editing.
Channel A – Directly chooses the measurement function (V, A, Ω or W).
Channel B – Selects the source function (V or A) and places cursor in the source field.
Channel B – Cycles through measure functions (V, A, Ω or W).
Channel B – Places the cursor in the compliance limit field for editing.
Channel B – Directly chooses the measurement function (V, A, Ω or W).
Channel A – Changes display resolution to 4-1/2, 5-1/2, or 6-1/2 digits.
Channel A – Sets the measurement speed by controlling the A/D converter measurement
aperture.
Channel A – Controls relative, which allows a baseline value to be subtracted from a
reading.
Channel A – Controls the digital filter, which can be used to reduce reading noise.
Channel B – Changes display resolution to 4-1/2, 5-1/2, or 6-1/2 digits.
Channel B – Sets the measurement speed by controlling the A/D converter measurement
aperture.
Channel B – Controls relative, which allows a baseline value to be subtracted from a
reading.
Channel B – Controls the digital filter, which can be used to reduce reading noise.
Loads factory or user-defined scripts for execution.
Runs last selected factory or user-defined scripts.
Stores readings, source values, and timestamp values in one of two internal buffers per
channel for later recall.
Recalls stored readings, source values, and timestamp values from either of the two buffers.
Triggers readings.
Accesses the Main Menu for saving and recalling setups, selecting remote interface, line
frequency, self-tests, serial number and beeper control.
Cancels selection, and backs out of menu structure. Used as a LOCAL key to take the unit
out of remote.
Accepts selection, moves to next choice or exits menu.
Return to
Section Topics
Series 2600 System SourceMeter
2600S-900-01 Rev. C / January 2008
®
Instruments User's Manual