e) If IP-900E/IP-900D/IP-900IID is supplied from the power strip or the
service outlet of other units, it may overload the power supply cord of
the power strip or other units.
Confirm that the current rating of the power strip or the service
-
outlet exceeds the combined ratings of all equipment is supplying.
-
The electrical rating of IP-900E : Rated 100-240 VAC, 50/60 Hz, 1
phase, 0.38 - 0.20 A(IP-900E)/0.33 - 0.17 A(IP-900D) /0.35 - 0.18 A
(IP-900IID).
f) The reliable earthing of the rack-mounted equipment must be
maintained.
connections other than direct connections to the branch circuit (e.g.,
use of the power strips or the power distribution unit).
Note: The high leakage current may flow through the power strip
earthing
IP-900E/IP-900D/IP-900IID are connected to one power strip. The
earth connection is essential before connecting supply. If the power
strip is not directly connected to the branch circuit, the power strip
which has the industrial type attachment plug should be used.
2.1.3
Air supply and exhaust of the equipment
IP-900E/IP-900D/IP-900IID is forced air cooled equipment.
intake/exhaust vents. Provide an adequate amount of space around the vents.
The particular attention should be given to supply
conductor
if
all
33
Chapter 2 Installation and Connection
power
supply
Be sure not to block the air
IP-900E/IP-900D/IP-900IID
cords
of