Chapter 2 Installation and Connection
2) rack mounting
a) When IP-9610 is installed in a closed or multi-unit rack, the operating
b) The installation of IP-9610 in a rack should be such that the amount of airflow
c) The mounting of IP-9610 in a rack should be such that a hazardous condition
d) If IP-9610 is supplied from the power strip or the service outlet of other units,
e) The reliable earthing of the rack-mounted equipment must be maintained.

2.1.3 Air flow into and out from the device

IP-9610 is forced air cooled. Be sure not to block the air intake/exhaust vents. Provide an
adequate amount of space around the vents.
IP-9610
ambient temperature inside of the rack environment may be greater than
room ambient. Therefore, the consideration should be given to operate in
the environment compatible with the specifications in Appendix 2.2
"Environment Specifications."
-
The consideration for adjustment of the air condition like air circulation
should be given to prevent the internal rack ambient from exceeding the
maximum operating ambient temperature of IP-9610.
-
The maximum operating ambient temperature for IP-9610: 50°C.
required for safe operation of IP-9610 is not compromised.
-
IP-9610 has ventilation opening at the left and rear side.
-
Do not cover or close these ventilation openings to prevent overheating.
in not archived due to uneven mechanical loading. To keep stability of the
entire rack, please fix the rack to wall or floor by suitable means.
-
Be careful about injury during installation of IP-9610 into rack.
-
Do not install IP-9610 into your rack where IP-9610 may make the entire
rack unstable.
-
The weight of IP-9610 with the maximum configuration: 7 kg
it may overload the power supply cord of the power strip or other units.
-
Confirm that the current rating of the power strip or the service outlet
exceeds the combined ratings of all equipment is supplying.
-
The electrical rating of IP-9610: Rated 100-240 VAC, 1.70-0.71 A, 50/60 Hz,
1 phase.
The particular attention should be given to supply connections other than
direct connections to the branch circuit (e.g., use of the power strips or the
power distribution unit).
Note: The high leakage current may flow through the power strip earthing
conductor if all power supply cords of IP-9610 are connected to one power
strip. The earth connection is essential before connecting supply. If the power
strip is not directly connected to the branch circuit, the power strip which has
the industrial type attachment plug should be used.