Chapter 5 Troubleshooting
5.2
5.2
This section describes corrective actions to take if an alarm LED turns on.
The appropriate corrective action depends on the alarm code displayed. See the table below for this
information.
See Software User's Guide for information how to check the alarm log check and an
example with displayed information.
Code
Lxxx
L001
L006
L009
L00A
L010
Ixxx
I001
(Only IP-900E)
I002
(Only IP-900E)
I003
(Only IP-900E)
I011
(Only IP-900E)
I021
(Only
IP-900D/IID)
Exxx
xxx: Indicates a three-digit numeric value. See Software User's Guide.
In addition, LED display details are given in the following table:
IP-900E/IP-900D/IP-900IID
Alarm LED Lamp
Table 5.2 Alarm codes and corrective actions
LAN network related alarms are shown as "Lxxx". Alarm LED is not turned on. Each
code's description and the countermeasures are shown below. Check the network and
destination device. If an error cannot be identified or recovered, contact your system
administrator or Fujitsu CE.
LAN is not connected. Check the connecting status of LAN cable and the settings of the
network equipment such as hub.
Time synchronization with the time server is failed. Check time server and the related
settings of this equipment and whether the server works correctly or not.
Failed to establish DHCP connection. Check DHCP server and the related settings of this
equipment and whether the server works correctly or not.
Failed to establish PPPoE connection. Check PPPoE related settings and whether the
server (provider side) works correctly or not.
Failed to IPv6 Stateless Address Autoconfiguration. Check IPV6 router and the related
settings of this equipment and whether the router works correctly or not.
This alarm is related with input status. Each INDWN LED (IP-900E) and DEC LED
(IP-900D) is turned on or blinked. Each code's description and the countermeasures are
shown below. If an error cannot be identified or recovered, contact your system
administrator or Fujitsu CE.
No SDI input signals. Check SDI output equipment and SDI cable which are connected to
SDI input terminal. INDWN LED is turned on in orange.
No HDMI input signals. Check HDMI output equipment and HDMI cable which are
connected to HDMI input terminal. INDWN LED is turned on in orange.
No Analog video input signals. Check Analog video output equipment and analog video
cable which are connected to Analog video input connector. INDWN LED is turned on in
orange.
Synchronization error with input signals. Check whether format settings of this equipment
for the signal are adequately specified or not. INDWN LED blinks in orange.
Errors are detected in the received stream data. Check whether the using rate of sending
side (Encoder) is appropriate for the network or not.
This alarm shows the error of this equipment and ALM LED is turned the light on or
blinked. Turn off the equipment at once and turn on the power again. In case of not turning
off ALM LED even if you reboot the power, contact Fujitsu CE. Our CE may ask you the
alarm code. Please refer to "Table 4-3 Alarm Code List" of our software Users Guide for
the details.
Corrective action
72

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ip-900dIp-900iid