Parameter 57: Auto Mode Sounder On/Off - Honeywell FBII CP-220A Hookup And Installation Instructions

Central station receiver
Table of Contents

Advertisement

REMEMBER!
To leave the Programming
Mode at any time, press
the Esc key. Doing so will
return the CP-220A to its
normal operating mode.
Programming changes will
be stored automatically.
PARAMETER 57:
Auto Mode
Sounder On/Off
Page 2-50 Section 2: Programming the CP-220A CP-220A Central Station Receiver
3.
Press the
key so that the [1] after [SLOT] flashes again.
4.
To change another slot, press the number key of the slot desired (e.g.,
2); the chosen Slot Number and the currently assigned handshake tone
duration will be displayed.
5.
Repeat the above steps for each Slot Number whose handshake tone
duration must be changed.
Default:
Each Line Card is factory programmed to produce a 1-second handshake
tone for each of the fixed (2300 Hz and 1400 Hz) frequencies.
Advancing to Next Parameter:
After programming PARAMETER 56, press the N key to advance to
PARAMETER 57 – the next parameter in Category A.
The CP-220A displays the parameter just programmed ([PARAMETER
NUMBER 56]) with its first digit flashing, indicating its request for the next
parameter number.
You can reach PARAMETER 57 in one of several ways. Press either:
• 5 then 7 , or
then 7 , or
• the
NOTE: When the
immediately – not its number.
AUTO MODE SOUNDER OFF M/DD/YY HH:MM:SS
Background:
PARAMETER 57 is an adjunct to PARAMETER 04 (as was PARAMETER
37; see pages 2-9 and 2-38), which was used to globally enable or disable the
CP-220A's Internal Sounder. This sounder is intended to call the operator's
attention to an incoming data transmission or to an error message. If it's
"globally" enabled (in PARAMETER 04), and the CP-220A is being operated
in the AUTOMATIC Mode (see page 2-103), the sounder will function
according to how PARAMETER 57 is programmed.
Keep in mind that, when in the AUTOMATIC mode, the CP-220A does not
display any incoming messages, but routes them instead to the attached
printer and (if used) automation system for direct processing.