Honeywell AlarmNet 7810iR-ent Installation And Setup Manual

Honeywell AlarmNet 7810iR-ent Installation And Setup Manual

Internet/intranet ip alarm receiver
Table of Contents

Advertisement

K9581V8 6/09 Rev. B
A
l
a
r
m
N
A
l
a
r
m
N
I
n
t
e
r
n
e
t
/
I
n
t
r
I
n
t
e
r
n
e
t
/
I
n
t
r
Installation and Setup Guide
e
t
7
8
1
e
t
7
8
1
a
n
e
t
I
P
A
l
a
r
a
n
e
t
I
P
A
l
a
r
0
i
R
-
e
n
t
0
i
R
-
e
n
t
m
R
e
c
e
i
v
e
r
m
R
e
c
e
i
v
e
r

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell AlarmNet 7810iR-ent

  • Page 1   Installation and Setup Guide K9581V8 6/09 Rev. B...
  • Page 3: Table Of Contents

    Table of Contents SECTION 1 ............................1-1 General Information ........................1-1 About the AlarmNet Enterprise Application ......................... 1-1 About the AlarmNet-i Internet Application .......................... 1-1 Encryption (AlarmNet-i Application) ........................... 1-1 Encryption (Enterprise Application) ............................. 1-2 Installation Key (Enterprise Application) ..........................1-2 Recovery Mode (Enterprise Application) ..........................
  • Page 4 7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide SECTION 5 ............................5-1 Operation ............................5-1 General Information ................................5-1 Manual Mode ..................................5-1 Alarm Sequence in Manual Mode ........................... 5-1 LRR Line Card Mode ................................5-3 Alarm Sequence in LRR Line Card Mode ........................5-3 685 Automation Mode ................................
  • Page 5: General Information

    KEY used to encrypt the data. Each device produced by Honeywell is loaded with a globally unique identifier called a MAC number, and a large random number or KEY. This KEY and MAC number are also stored in the AlarmNet servers.
  • Page 6: Encryption (Enterprise Application)

    7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide 1.0 contained in the Honeywell products has NIST approval. Listings for this approval can be found at http://csrc.nist.gov/cryptval/aes/aesval.html Certification number 127. Encryption (Enterprise Application) The previous paragraph described general encryption, and how it functions with AlarmNet.
  • Page 7: 7810Ir-Ent Backup Receiver (Enterprise Application)

    Section 1: General Information 7810iR-ent Backup Receiver (Enterprise Application) Backup receiver is supported for Private LAN configuration only. AlarmNet-i configuration doesn’t support backup receiver. The main objective of the backup receiver is to support un- interrupted alarm reporting when the primary receiver fails. The backup receiver assumes the responsibility of the primary receiver in case of a primary receiver failure.
  • Page 8 7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide The Remote Access feature and uploading/downloading of control panel data over IP have not been evaluated by UL. These functions are performed by the automation software connected to the 7810iR-ent. • When concurrent signals are received, they are displayed in descending order of priority. •...
  • Page 9: Section 2

    S E C T I O N 7810iR-ent Setup • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Mounting the 7810iR-ent The 7810iR-ent is intended for dry, indoor use only.
  • Page 10: Power Requirements

    For ULC installations, the DC power supply must be a CUL or CSA Listed, regulated 12VDC, min. 500mA Commercial Fire Alarm power supply, or two UL Listed Class 2 Honeywell Model 7720V2TR-CNs powered by a CUL or CSA Listed Commercial Fire Alarm UPS with audible and visual indications of switchover to secondary power.
  • Page 11 Section 2: 7810iR-ent Setup Figure 1a. 7810iR-ent Manual Mode Wiring Diagram using Honeywell Model 7720V2TRs If using a UL Listed, regulated 12VDC, min. 500mA Commercial Fire Alarm power supply, follow the method of wiring shown below. Figure 1b. 7810iR-ent Manual Mode Wiring Diagram using a UL1481 Listed Power Supply...
  • Page 12: Lrr Line Card Mode

    For ULC installations, the DC power supply must be a CUL or CSA Listed, regulated 12VDC, min. 500mA Commercial Fire Alarm power supply, or two UL Listed Class 2 Honeywell Model 7720V2TR-CNs powered by a CUL or CSA Listed Commercial Fire Alarm UPS with audible...
  • Page 13 For ULC installations, the DC power supply must be a CUL or CSA Listed, regulated 12VDC, min. 500mA Commercial Fire Alarm power supply, or two UL Listed Class 2 Honeywell Model 7720V2TR-CNs powered by a CUL or CSA Listed Commercial Fire Alarm UPS with audible and visual indications of switchover to secondary power.
  • Page 14: 685 Automation Mode

    For ULC installations, the DC power supply must be a CUL or CSA Listed, regulated 12VDC, min. 500mA Commercial Fire Alarm power supply, or two UL Listed Class 2 Honeywell Model 7720V2TR-CNs powered by a CUL or CSA Listed Commercial Fire Alarm UPS with audible and visual indications of switchover to secondary power.
  • Page 15 Section 2: 7810iR-ent Setup 2. Connect the 12V AUX terminal (pin 1) of the 7810iR-ent to the DC (+) terminal of a 7720V2TR power supply. Connect a jumper between 12V AUX terminal (pin 1) and 12V IN (pin 2, RED). 3.
  • Page 16 7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Figure 3a. 7810iR-ent MX8000 LRR Line Card Wiring using Honeywell Model 7720V2TRs Figure 3b. 7810iR-ent 685 Automation Mode Wiring using Honeywell Model 7720V2TRs If using a UL Listed, regulated 12VDC, min. 500mA Commercial Fire Alarm power supply,...
  • Page 17 Section 2: 7810iR-ent Setup Figure 3c. 7810iR-ent MX8000 LRR Line Card Wiring using a UL1481 Listed Power Supply Figure 3d. 7810iR-ent 685 Automation Mode Wiring using a UL1481 Listed Power Supply...
  • Page 18: Serial Printer Installation

    For ULC installations, the DC power supply must be a CUL or CSA Listed, regulated 12VDC, min. 500mA Commercial Fire Alarm power supply, or two UL Listed Class 2 Honeywell Model 7720V2TR-CNs powered by a CUL or CSA Listed Commercial Fire Alarm UPS with audible and visual indications of switchover to secondary power.
  • Page 19: Section 3

    S E C T I O N Navigation and Basic Feature Tour • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Home Screen The 7810iR-ent uses a Graphical User Interface (GUI).
  • Page 20: Navigation

    7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide ITEM FUNCTION Used to silence new alarms and move them to the Alarm History Display Next button window. Navigation From the Home Screen, press the Setup Button: When navigating from any 7810iR-ent screen: button returns the user to the Home screen, button returns the user to the previous screen.
  • Page 21 Section 3: Navigation and Basic Feature Tour Indicates remote access is disabled. To enable remote access, press this button. From the Basic Setup screen, Figure 5. Advanced Setup Screen From the Advanced Setup Screen, the user can setup account information, set network connectivity options, perform diagnostics, download the latest application code, read file system statistics.
  • Page 22 7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide...
  • Page 23: Section 4

    S E C T I O N Programming • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • UL864 Requirements This product incorporates field-programmable software.
  • Page 24 7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Action Screen Display 2. Press the Advanced Setup button. 3. Enter the Authorized Code using the displayed keypad. NOTE: The default Authorized Code for the 7810iR-ent is 7810. 4. After the Authorized Code has been verified, press the Central Station button.
  • Page 25 Section 4: Programming Action Screen Display 6. For Private LAN configuration, select Private LAN Only. Select the Account tab. NOTE: When Private LAN Only checkbox is selected or deselected, 7810iR-ent resets after “Back” or “Home” button is pressed. 7. Enter City ID, CS ID and Sub ID by touching each field and using the keypad.
  • Page 26 7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Action Screen Display 8. Enter Old Alarm Time, Fault Time Minutes and Account Supervision type. Select Reg/Test tab. Important - For Private LAN configuration only setup; Old Alarm Time, Fault Time Minutes and Account Supervision are not used and can be left at the default values.
  • Page 27 Section 4: Programming Action Screen Display 11. Registration is not required for a Private System. Touch No. NOTE: Touching Yes will not cause any problems. 12. You are returned to this screen.
  • Page 28: Installing The 7810Ir-Ent For Private Lan

    7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Installing the 7810iR-ent for Private LAN 7810iR-ent uses a one time Installation Key to install all 7845i-ent’s that have been properly programmed and connected to the network. Up to 225 7845i-ent’s can be installed using one 10-digit key.
  • Page 29 Section 4: Programming Action Screen Display 3. Enter the Authorized Code using the displayed keypad. NOTE: The default Authorized Code for the 7810iR-ent is 7810. 4. After the password has been verified, press the Central Station button. 5. Press the Install 7810iR button. 6.
  • Page 30 7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Action Screen Display 7. Enter the 10 digit Installation Key. This is the same key that should have been programmed into all 7845i-ent’s being installed. 8. Re-enter 10-digit Installation Key for verification. If Installation Key entry is verified then 7810iR-ent will automatically return you to the previous screen.
  • Page 31 Section 4: Programming Action Screen Display 11. Enter Authorized Code (7810 is the default). 12. To view active subscribers. Active Subs: Shows the total number of subscribers. Comm Failed Subs: Show the total number of units with a communications failure (CF). Substitution Subs: Shows how many units have been enabled for substitution.
  • Page 32 7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Action Screen Display 14. The Account Status window allows the user to view detailed information on any subscriber. Delete: deletes all Subscriber account information. Substitute: allows an Installer to substitute one 7845i-ent with a new unit using the same account number.
  • Page 33: 7810Ir-Ent Backup Receiver Configuration

    Section 4: Programming 7810iR-ent Backup Receiver Configuration Primary Receiver Configuration Action Screen Display 1. To program primary 7810iR-ent touch the AlarmNet button. 2. Touch the Advanced Setup button. 3. Enter the Authorized Code using the displayed keypad. NOTE: The default Authorized Code for the 7810iR-ent is 7810.
  • Page 34 7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Action Screen Display 4. After the Authorized Code has been verified, touch the Central Station button. 5. Touch the Install 7810iR button. 6. Primary receiver can be configured as shown: Configure all parameters: •...
  • Page 35: Backup Receiver Configuration

    Section 4: Programming Backup Receiver Configuration Action Screen Display 1. To program primary 7810iR-ent touch the AlarmNet button. 2. Touch the Advanced Setup button. 3. Enter the Authorized Code using the displayed keypad. NOTE: The default Authorized Code for the 7810iR-ent is 7810. 4.
  • Page 36 7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Action Screen Display 5. Touch the Install 7810iR button. 6. Backup receiver can be configured as shown: Configure all parameters: • Select role of This 7810iR as Secondary • Select role of Other 7810iR as Primary •...
  • Page 37: Recovery Mode (Private Lan Only)

    Section 4: Programming Action Screen Display 7. To enter 10-digit installation key, Enter the 10-Digit Installation Key. Important: The installation key must match the primary CS installation key. 8. Re-enter 10-digit installation key for verification. If the Installation Key entry is verified then 7810iR-ent will automatically return you to the previous screen.
  • Page 38: Subscriber Database (Private Lan Only)

    7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Action Screen Display 3. Re-enter the 10-digit Installation Key for verification. If Installation Key entry is verified then 7810iR-ent will automatically return you to the previous screen. 4. The Recovery Mode button will be lit green indicating that the 7810iR-ent is attempting to recover all accounts.
  • Page 39 Section 4: Programming Action Screen Display 2. Touch the Advanced Setup button. 3. Enter the Authorized Code using the displayed keypad. NOTE: The default Authorized Code for the 7810iR-ent is 7810. 4. Touch the Central Station button. 5. Touch the Clear Database button. 4-17...
  • Page 40: Subscriber Database Synchronization

    7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Action Screen Display 6. Press to permanently delete subscriber database. The subscriber database is permanently removed and 7810iR-ent resets. Subscriber Database Synchronization Automatic Synchronization of the Subscriber Database Backup receiver subscriber database is updated automatically under the following circumstances.
  • Page 41 Section 4: Programming Action Screen Display 1. To perform the subscriber database synchronization, touch the AlarmNet button. 2. Touch the Advanced Setup button. 3. Use the keypad to enter the Authorized Code. The default Authorized Code for 7810iR-ent is: 7810. 4.
  • Page 42 7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Action Screen Display 5. Touch the Install 7810iR button. 6. Touch the Synchronize Database button. 7. To update the primary receiver subscriber database from the backup receiver, To update the backup receiver subscriber database from the primary receiver, 8.
  • Page 43 Section 4: Programming Action Screen Display 9. If Synchronize the (back up) Secondary CS is touched then a confirmation window is displayed. Touch OK to continue. Touch Cancel to cancel the operation. 10. Synchronization successful message is displayed when the subscriber database synchronization is successfully completed.
  • Page 44: Network Settings

    7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Network Settings Action Screen Display 1. Touch the AlarmNet button. 2. Touch the Advanced Setup button. 3. Use the keypad to enter the Authorized Code. The default Authorized Code for 7810iR-ent is: 7810. 4.
  • Page 45 Section 4: Programming Action Screen Display 5. For a Private LAN installations, MAC Address is unique for each unit and will not change. DHCP should be de-selected. IP Address: Get a static IP address from Network Administrator. Subnet Mask: Get subnet mask from Network Administrator Gateway IP Address: Get it from Network Administrator...
  • Page 46: Subscriber Commands

    7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Subscriber Commands Subscriber Network Services (Telnet/FTP) Subscriber network services like Telnet & FTP can be enabled or disabled from primary 7810iR-Ent. Subscriber network services cannot be enabled/disabled from secondary 7810iR-Ent. As a part of subscriber details screen, 7810iR-Ent provides user interface to enable/disable subscriber network services.
  • Page 47 Section 4: Programming Action Screen Display 4. Touch Display to view accounts list. 5. Touch Enabled to view subscriber account details. 6. Periodically, the subscriber IP header is updated with subscriber’s IP address. Important: If subscriber is behind firewall/router then firewall/router IP address is displayed.
  • Page 48 7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Action Screen Display 7. Select Enable Telnet, Enable FTP or both and activate changes by pressing Send Command. Note: If only Enable Telnet is selected, Telnet is enabled and FTP is disabled. Likewise, if only Enable FTP is selected, FTP is enabled and Telnet is disabled.
  • Page 49: Subscriber Software Update

    Section 4: Programming Subscriber Software Update This feature allows installer to update subscriber software. Subscriber Software Update has not been evaluated by UL. Action Screen Display 1. Touch the Software Update URL data entry field. The Enter Data screen is displayed.
  • Page 50: Test Alarm

    7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Test Alarm This feature allows 7810iR-ent to force a test alarm to be sent. A subscriber can select to send test alarm to only primary, to only secondary or to both primary and secondary. If a secondary 7810iR-ent is not configured then options “Second”...
  • Page 51: Programming Alarmnet-I Subscriber Information

    Section 4: Programming Action Screen Display A confirmation window is displayed to indicate the changes have been queued. Programming AlarmNet-i Subscriber Information Action Screen Display 1. From the Home Screen, navigate to the Central Station Setup Screen: Enter authorization code. 2.
  • Page 52 7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Action Screen Display 4. Select Use Master Account # button only if the Master Account number is to be used as the AlarmNet account. Otherwise, touch each data field and enter the required account information.
  • Page 53: Registration

    Section 4: Programming Registration Action Screen Display 1. Select Reg/Test tab. To Register 7810iR-ent with AlarmNet, 2. The Please Register button text changes to display Registering. In the top-most right status box (there are seven status boxes on the right of the screen), the Not Registered text changes to Registration Sent OK indicating that registration is in process.
  • Page 54: Programming Automation Options

    7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Programming Automation Options Action Screen Display 1. From the Home Screen, navigate to the Central Station Setup Screen: Enter Authorized Code. 2. After the Authorized Code has been verified, 3. Touch Auto Opt tab. There are three possible configurations for Automation.
  • Page 55 Section 4: Programming Action Screen Display 4b. LRR Line Card mode is used when the 7810iR-ent will communicate with a digital receiver. Baud rate is set by the line card at 19.2 kb/s. Select the Fail to Manual button if this feature is required. 4c.
  • Page 56 7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Action Screen Display 5. To use Virtual Private Network (VPN), one or more additional Central Station ID’s, each greater than the CS number programmed into the 7810iR-ent, must be assigned by AlarmNet. The VPN Enable button must be selected as shown.
  • Page 57: Operation

    S E C T I O N Operation • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • General Information One of the three modes of operation, Manual, LRR Line Card and 685 Automation must be selected during the 7810iR-ent programming.
  • Page 58 7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Action Screen Display 3. Operator takes appropriate action for Subscriber. to move message from New Alarm window to Alarm History window and display the next alarm in the buffer. 4. Waiting for next alarm.
  • Page 59: Lrr Line Card Mode

    Section 5: Operation LRR Line Card Mode When configured for LRR Line Card Mode, subscriber alarm messages received on the 10BaseT connection are passed to a 685-5 line card installed in a 685 Digital Alarm Receiver or a LRR Line card in an MX-8000. New alarms are briefly displayed in the 7810iR-ent New Alarm window with no audible alert.
  • Page 60 7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Fail to Manual If Fail to Manual is selected and there is a loss of communication between the 7810iR-ent and the LRR Line Card, an incoming message will be reported as undeliverable to AlarmNet after approximately 30 seconds.
  • Page 61 Section 5: Operation Mode Override Feature Mode Override allows the operator to manually switch to Manual Mode. This feature is only available when Fail to Manual has been selected during programming. Action Screen Display . Deselect the Auto button to enter Manual Mode. clears any messages in the New Alarm Buffer.
  • Page 62: 685 Automation Mode

    7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide 685 Automation Mode When configured for 685 Automation Mode, subscriber alarm messages received on the 10BaseT connection are routed directly to Automation equipment. Using an RS232 serial interface, the 7810iR-ent communicates with Automation equipment in the same way as a 685 Digital Alarm Receiver.
  • Page 63 Section 5: Operation Fail to Manual If Fail to Manual is selected and there is a loss of communication between the 7810iR-ent and the Automation system, an incoming message will be reported as undeliverable to AlarmNet after approximately 30 seconds. AlarmNet will then route all messages to the secondary CS path (AlarmNet-i, AlarmNet-M or 800 PLUS).
  • Page 64 7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Mode Override Feature Mode Override allows the operator to manually switch to Manual Mode. This feature is only available when Fail to Manual has been selected during programming. Action Screen Display . Deselect the Auto button to enter Manual Mode.
  • Page 65: Backup Receiver Operation (Private Lan Only)

    Section 5: Operation Backup Receiver Operation (Private LAN only) In an installation with two 7810iR-ents, one is configured as primary receiver and the other as backup receiver. Each subscriber (7845i-ent) in the system is configured with IP addresses of both primary and backup 7810iR-ent in the system. Normal Operation All normal reporting is done to primary receiver.
  • Page 66 7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide 5-10...
  • Page 67: Section 6

    S E C T I O N Message Formats • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Message Formats There are two categories of messages that are sent by AlarmNet to the Central Station.
  • Page 68: How Contact Id Is Displayed On The Printer When Using Lrr Line Card Mode

    7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide How Contact ID is Displayed on the Printer when using LRR Line Card Mode How Contact ID Messages are sent to Automation Equipment in 685 Automation Mode...
  • Page 69: Ademco High-Speed Format

    Section 6: Message Formats ADEMCO High-Speed Format Consists of: A 4-digit subscriber ID • Eight channels of information indicating zones or other information in each message • A ninth status digit indicating the type of report • How High-Speed is Displayed on the 7810iR-ent How High-Speed is Displayed on the 685 Receiver How High-Speed is Displayed on the Printer when using LRR Line Card...
  • Page 70: How High Speed Messages Are Sent To Automation Equipment In 685 Automation Mode

    7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide How High Speed Messages are sent to Automation Equipment in 685 Automation Mode Reading a High Speed Message The status channel (9th channel identifies the type of message, as shown below. • 0 = Diagnostic Messages 1 = Notification Message 2 = Not applicable to radio accounts...
  • Page 71: Status Channel = 0 (Diagnostic Message)

    Section 6: Message Formats Status Channel = 0 (Diagnostic Message) Message Definition Applies to Key Indicator: “F” in 2nd channel cccc ngF0 s0fm 0 F-Type diagnostic (RF) n = number of the node reporting (1-9, A-F) g = node group number (0 or 1) F = F-type diagnostic s = signal strength (0-9, or A) f = frequency (always “0”, not used)
  • Page 72 7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Message Definition Applies to Key Indicator: “A” in 3rd channel cccc ngA0 s 0fm 0 A-type dia gnos tic (RF) n = numbe r of the node re porting (1-9, A-F) g = node group numbe r (0 or 1) A = A-type dia gnos tic s = s igna l s tre ngth (0-9, or A) f = fre que ncy (a lwa ys “0”, not us e d)
  • Page 73 Section 6: Message Formats Message Definition Applies to 0000 ngD0 00DB 0 Database update in progress n = number of the node reporting (1-9, A-F) g = node group number (0 or 1) D0 = indicates this node is being updated 00DB = indicates a database update Key Indicator: “E”...
  • Page 74: Status Channel = 1 (Notification Message)

    7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Status Channel = 1 (Notification Message) Message Definition Applies to 0000 5555 5555 1 Network Alert Message – Tells the C/S to refer to their e-mail or fax machine for further information and instructions from AlarmNet. cccc 5555 1555 1 Secondary CS Communications Failure A/M/C...
  • Page 75: Status Channel = 6 (Status Message)

    Section 6: Message Formats Message Definition Applies to cccc 5555 5515 5 Los s of ECP S upe rvis ion 7845C, 7845CZ a nd (‘Ma s te r Hos t’ type me s s a ge for a n individua l 7845i-e nt s ubs cribe r) Applie s to 7845C whe n us e d in 4229 or 4204 mode s...
  • Page 76: Status Channel = 7 (Alarm Condition)

    7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Message Definition Applies to cccc 5555 5535 6 S ys te m S upe rvis ory Fa ult Re s tore 7720ULF cccc 5555 5565 6 S ys te m S upe rvis ory Fa ult P re vious ly Re porte d 7720ULF cccc 5555 5551 6 Wa lk Te s t...
  • Page 77: Status Channel = 8 (Alarm With Low Battery (Older 7620 Radio Only)

    Section 6: Message Formats Message Definition Applies to wired to the alarm control so that a signa l is s e nt to the Disarmed Armed ra dio whe n the a la rm is (Opening) or (Closing). Note regarding the 7620ULF: Due to the fact that the 7620ULF is not a fire alarm control, supervisory faults from the fire control panel may be used to trigger one or more of the eight channels on the 7620ULF, and thus will...
  • Page 78: Status Channel = 9 (Installer Generated Test Message)

    7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Status Channel = 9 (Installer generated test message) Message Definition Applies to cccc 5555 5555 9 System Test Message Manually triggered test from the radio. Test signal generated by an AlarmNet Network Technician for a specific subscriber.
  • Page 79 Section 6: Message Formats Water flow Fire -Wa te r Flow -# He a t Fire -He a t S e ns or-# P ull S ta tion Fire -P ull S ta tion-# Duct Fire -Duct S e ns or-# Fla me Fire -Fla me S e ns or-# Ne a r Ala rm...
  • Page 80 7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Wa te r Le a ka ge Ala rm-Wa te r Le a ka ge -# Foil Bre a k Trouble -Foil Bre a k-# Da y Trouble Trouble -Da y Zone -# Low Bottle d Ga s Le ve l Ala rm-Low Ga s Le ve l-# High Te mp...
  • Page 81 Section 6: Message Formats Trouble Re la y Trouble -Trouble Re la y Re ve rs ing Re la y Trouble -Re ve rs ing Re la y Notifica tion Applia nce Ckt. # 3 Trouble -Notifica tion Appl. Ckt#3 Notifica tion Applia nce Ckt.
  • Page 82 7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Fire Trouble Trouble -Fire Loop-# (S upe rvis ion Los s ) Exit Error (By Us e r) Ala rm-Exit Error-# P a nic Zone Trouble Trouble -P A Trouble -# Hold-Up Zone Trouble Trouble -Hold-Up Trouble -# Sensor S e ns or Trbl - Globa l...
  • Page 83 Section 6: Message Formats Fa ile d to Clos e Trouble -Fa il to Clos e (Re s tore not a pplica ble ) Auto-Arm Fa ile d Trouble -Auto Arm Fa ile d (Re s tore not a pplica ble ) P a rtia l Arm Clos ing-P a rtia l a rm-Us e r # Exit Error (Us e r)
  • Page 84 7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Sounder/Relay Disables S ounde r/Re la y Dis a ble Dis a ble -S ounde r/Re la y-# Be ll 1 Dis a ble Dis a ble -Be ll/S ire n # 1 Be ll 2 Dis a ble Dis a ble -Be ll/S ire n # 2 Ala rm Re la y Dis a ble...
  • Page 85 Section 6: Message Formats Intrus ion Zone Wa lk Te s te d Te s t-Intrn Zone Wa lk Te s t-# (Re s tore Not Applica ble ) Fire Zone Wa lk Te s te d Te s t-Fire Zone Wa lk Te s t-# (Re s tore Not Applica ble ) P a nic Zone Wa lk Te s te d Te s t-P A Zone Wa lk Te s t (Re s tore Not Applica ble ) S e rvice Re que s t...
  • Page 86 7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide 6-20...
  • Page 87: Section 7

    S E C T I O N Diagnostics and Troubleshooting • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Diagnostics About Diagnostics A series of diagnostic and calibration tests is provided that allows verification of correct...
  • Page 88: Performing Diagnostics

    7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Action Screen Display 2. Press the Diagnostics button on the Advanced Setup Screen. The "Diagnostics" screen is displayed. (For AlarmNet Only.) NOTE: 7810iR-ent Diagnostics cannot be run using Remote Access feature and will not run locally if a Remote Access session is active.
  • Page 89: Lcd Display Test

    Section 7: Diagnostics and Troubleshooting LCD Display Test Perform the LCD Display Test as follows: Action Screen Display 1. When you press the Test button associated with the Display Test, a pop-up "Confirmation Window" is displayed in the center of the screen with an all green background.
  • Page 90 7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Action Screen Display 5. When you press the Yes or No button accordingly, automatically the contrast test begins from low to high. "Changing Contrast.." is displayed in the center of the screen during this time.
  • Page 91: Real Time Clock Test

    Section 7: Diagnostics and Troubleshooting Real Time Clock Test Perform the Real Time Clock Test as follows: Action Screen Display Press the Test button associated with the Real time clock test. "Please Wait" is displayed in the test status column on the "Diagnostics" screen.
  • Page 92: Audio Test

    7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Audio Test Perform the Audio Test as follows: Action Screen Display 1. Press the Test button associated with the Audio Test. "Please Wait " is displayed (yellow) in the test status column on the "Diagnostics"...
  • Page 93: Led Test

    Section 7: Diagnostics and Troubleshooting LED Test Perform the LED Test as follows: Action Screen Display 1. Press the Test button associated with the LED Test. "Please Wait " is displayed (yellow) in the test status column on the "Diagnostics" screen while the 4 LEDs light sequentially, left to right (amber, red, green, green), five times.
  • Page 94: Touch Screen Calibration

    7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Touch Screen Calibration Calibrate the touch screen as follows: Action Screen Display 1. Begin the Touch Screen calibration from the "Diagnostics/Tests" screen by pressing the Calibrate button. When the Calibrate button is pressed, the Touch Screen Calibration screen is displayed.
  • Page 95 Section 7: Diagnostics and Troubleshooting Action Screen Display 3. Press the center of the square. The Touch Screen Calibration screen displays Next press the box in lower right corner. 4. Press the center of the square. The Touch Screen Calibration screen displays Next press the box in lower left corner.
  • Page 96: Encryption Algorithm Self-Test

    7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide Encryption Algorithm Self-Test Action Screen Display Encryption algorithm self-test functionality can be found under Advanced Setup -> Diagnostics -> Crypt Algorithm Test. Pressing the Test button performs a cryptographic algorithm self-test for AES and Blowfish algorithms.
  • Page 97 Notes...
  • Page 98 Notes...
  • Page 99 Notes...
  • Page 100 Notes...
  • Page 101 Notes...
  • Page 102 Regulatory Agency Statements FEDERAL COMMUNICATIONS COMMISSION (FCC) STATEMENTS The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment. CLASS B DIGITAL DEVICE STATEMENT NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
  • Page 103 For UL installations, the DC power supply must be a UL Listed, regulated 12VDC, min. 500mA Commercial Fire Alarm power supply, or two UL Listed Class 2 Honeywell Model 7720V2TRs powered by a UL1481 Listed UPS with audible and visual indications of switchover to secondary power.
  • Page 104 For the latest documentation and online support information, please go to: http://www.security.honeywell.com/hsc/resources/MyWebTech/ For the latest warranty information, please go to: http://www.security.honeywell.com/hsc/resources/wa/ 2 Corporate Center Drive, Suite 100 P.O. Box 9040 Melville, NY 11747 Copyright 2009 Honeywell International Inc. www.honeywell.com/security ÊK9581V8&Š K9581V8 6/09 Rev. B...

Table of Contents