Weekly; Removing The Ash; Annually; Carburisation Gas Duct - Windhager LOGWIN PREMIUM TOUCH Operating Manual

Wood gasification boiler
Hide thumbs Also See for LOGWIN PREMIUM TOUCH:
Table of Contents

Advertisement

3.
Care, cleaning and maintenance
3.2

Weekly

3.2.1 Removing the ash

Recommended cleaning implement: Scraper
– Attach ash pan at height of lighting door (central door) in the intended hook-in plate – Fig. 30. Open lighting door
and vertical grate and sweep most of the remaining ash from the filling chamber into the ash pan.
– Place ash pan under ash door (bottom door). Open ash door and carefully take all of the accumulated ash out of the
combustion chamber and ash chamber – Fig. 31.
Fig. 30
Attaching the ash pan, removing ash
DANGER
CAUTION
3.3

Annually

3.3.1 Carburisation gas duct

Recommended cleaning implement: Cleaning brush and vacuum cleaner
– Clean duct for carburisation gas extraction – Fig. 32.
Fig. 32
Cleaning the carburisation gas extraction
Risk of fire if ash has not cooled! Store ash in lockable and non-combustible container on
non-combustible base for at least 48 hours.
The ash may be loaded with heavy metals. Heavy metals may affect soil fertility. Ash
is not therefore suitable as a fertiliser and should be disposed of with residual waste.
Fig. 31
Removing ash from combustion chamber
and ash chamber
16
Holes in the
hook-in plates
Combustion
chamber
Ash chamber

Advertisement