9.2 Assembly
Assembling single Delta supports
Figure 103: Assembling Delta supports using single base rails
Delta supports with single base rails are supplied as complete, folded and pre-assembled units, including
three M8×50 hex screws with self-locking nut and tube sleeves. Secure the unfolded support using screw
connections. After having finished assembling, all screw connections must be tightened to 15 Nm.
Assembling continuous Delta support
Figure 104: Delta support with continuous base rail
Figure 105: Centering groove for drilling
Delta supports with continuous base rail are delivered as pre-assembled units without base rail. The
continuous base rail is delivered as 4.9m. The 12.5mm holes in the base rail must be drilled on site in the
centering groove. The hole spacing within the Delta support is 1290mm. The row spacing is individually
manufactured according to the project. Connect pre-assembled Delta supports to the base rail using two
screw connections. After having finished assembling, all screw connections must be tightened to 15 Nm.
59
Version 17.01, as of: 27-Jun-2017