Dimensioning:
Two-layer systems are dimensioned in the same way as single-layer systems. However, the following
special features must be taken into account:
Plan for one roof hook per area where carrier rail and roof hook connecting rail meet.
Please also take into account the static values of roof hook connecting rails in addition to the roof
hooks and carrier profiles. Use the PV Manager software to determine the static dimensions.
We do not recommend you exceed a maximum carrier rail length of 3 rods (approximately 15,60 m)
due to thermal expansion.
Figure 99 Cross section of a two-layer system structure
57
Version 17.01, as of: 27-Jun-2017
Roof hook
Two-layer connector
Max. 400mm
As per PV Manager
Max. ¼ of the module height (please observe module
manufacturer specifications)