Comply with the following requirements regarding the roof profile type:
The nominal sheet metal profile panel thickness around the fasteners is ≥ 0.4 mm for steel and ≥ 0.5
mm for aluminium.
The nominal width of the outer layer of the sandwich element around the fasteners is ≥ 0.4 mm.
The nominal width of the steel substructure (rafters/purlins) around the fasteners is ≥ 1.5 mm.
The available rib height h for sandwich roofs is 35 mm ≤ h ≤ 45 mm
The available upper belt width b for sandwich roofs is 20 mm ≤ b ≤ 40 mm
When putting a load on solar fasteners in a transverse direction to the profile panels, the profile
panels must be fastened to the corrugated elements on the substructure that are in the vicinity and at
the same height.
For additional framework conditions, see the valid version of the Z-14.4-638 certificate.