Step 7B: Affix the TRAPEZOIDAL CLAMP to the outer roofing with self drilling screws
When using the self drilling screws, two screws are placed per TRAPEZOIDAL CLAMP.
process, make sure you screw carefully to maintain static properties.
The
enclosed self drilling
0.5 mm to 1.5 mm.
Important:
A drill with a diameter of 5.0 mm is mandatory to maintain static properties
Figure 67 Apply the screw
Step 8A: Insert and affix the transverse securing clamp with blind rivets
The transverse securing clamps are affixed next to the trapezoidal clamp on the left and right with a
clearance of approximately 20 mm.
There must be a minimum of two transverse securing clamp per string (15.60 m).
Important:
Mount additional transverse securing clamps on roofs that are particularly exposed to wind.
Figure 69: Insert transverse securing clamps
42
Version 17.01, as of: 27-Jun-2017
screws 5,5x25
are approved for a sheet metal or aluminium thickness of
Figure 68 Trapezoidal clamp screwed
Figure 70: Drilling transverse securing clamps