34
MDS 9810 Installation and Operation Guide
Table 6. Command Summary (Continued)
COMMAND
ADDR [1...65000]
Details Page 36
AMASK [0000 0000–FFFF
FFFF]
Details Page 36
ASENSE [HI/LO]
Details Page 36
BAUD [xxxxx abc]
Details Page 36
BUFF [ON, OFF]
Details Page 37
CTS [0–255]
Details Page 37
DUMP
DEVICE [DCE, CTS KEY]
Details Page 38
HOPTIME [XSHORT, 16, 20,
25, 32, SHORT, NORMAL,
LONG]
Details Page 40
HREV
MODE [M, R, R-M]
Details Page 41
OWM
OWN
PWR [xx–30]
Details Page 42
RSSI
Details Page 42
RXTOT [NONE, 0–1440]
Details Page 43
SEND [n, -n, +n]
Details Page 43
SER
SHOW [PORT, DC, PWR]
Details Page 45
SIMPLEX [ON, OFF]
Details Page 45
SKIP [NONE, 1...8]
Details Page 46
SKIPSYNC [ON/OFF]
Details Page 46
DESCRIPTION
Network address (1-65000)
Sets alarm mask (response). Default is FFFF
FFFF.
Changes the sense of the alarm output. Default
sense is HI.
Display data communication parameters.
Example: BAUD 9600 8N1
Data buffering mode: ON = seamless data
OFF = fast byte throughput
CTS delay in ms (0-255 ms)
Show all settings. Use with PC-based Radio
Configuration software (P/N 03-3156A01).
Device behavior (DCE, or CTS KEY)
Show hop time in milliseconds (ms).
Hardware revision level
Show operating mode: M = Master, R =
Remote, R-M = Remote-Master (remote oper.
on master freqs.)
Owner's message or site name
Owner's name or system name
Forward power output setting in dBm
Received signal strength in dBm (continuously
updated). Not available at master radio unless
SETUP is enabled.
Specifies amount of time (in seconds) to wait
before issuing a time-out alarm. Default is
NONE.
Sets/displays re-send count for data packets.
Useful in areas with heavy radio interference.
Serial number of radio
Show active port, DC voltage or measured RF
power (dBm)
Simplex/half-duplex selection
ON = Simplex, OFF = half-duplex
Skip a frequency operating zone
When ON, suppresses transmission of SYNC
messages in skipped zones. Default setting is
OFF.
Display parameters continued...
MDS 05-3301A01, Rev. C
Need help?
Do you have a question about the MDS 9810 and is the answer not in the manual?