MDS 05-3301A01, Rev. C
Table 6. Command Summary (Continued)
COMMAND
ADDR [1...65000]
Details Page 36
AMASK [0000 0000–FFFF
FFFF]
Details Page 36
ASENSE [HI/LO]
Details Page 36
BAUD [xxxxx abc]
Details Page 36
CTS [0–255]
Details Page 37
CTSHOLD [0-6000]
Details Page 38
DEVICE [DCE, CTS KEY]
Details Page 38
INIT
Details Page 41
MODE [M, R, R-M]
Details Page 41
OWM [xxxxx]
Details Page 42
OWN [xxxxx]
Details Page 42
PWR [xx–30]
Details Page 42
RTU [ON/OFF/0-80]
Details Page 43
RXTOT [NONE, 0–1440]
Details Page 43
SEND [n, -n, +n]
Details Page 43
TDD [ON/OFF]
Details Page 47
UNIT [10000–65000]
Details Page 48
ZONE DATA
Details Page 49
ZONE CLEAR
Details Page 50
MDS 9810 Installation and Operation Guide
DESCRIPTION
Program network address
Sets alarm response. Default is FFFF FFFF.
Changes the sense of the alarm output. Default
sense is HI.
Set data communication parameters
Program CTS delay in milliseconds.
(A value of 0 returns CTS immediately)
Set/display "hold time" that CTS remains
present following last character transmission
from DD-25 port.
Set device behavior; DCE (normal) or CTS Key
(Repeater)
Initialize parameters to factory default values
Program operating mode, where M = Master,
R = Remote, R-M = Remote-Master (Remote
radio programmed to operate on Master fre-
quencies)
Program owner's message
(30 characters maximum)
Program owner's name
(30 characters maximum)
Program forward power output in dBm.
Re-enables or disables the radio's internal RTU
simulator and sets the RTU address.
Specifies max. duration (in minutes) to wait
before issuing a time-out alarm. Default is OFF.
Sets/displays re-send count for data packets.
Useful in areas with heavy radio interference.
Sets or displays time-division multiplex status of
DATA INTERFACE connector. (Sometimes
referred to as "simulated full-duplex" mode.)
Program unit address. Used to set a unique
address for network-wide diagnostics.
Show zone data statistics. Press "Q" to quit
Reset zone data statistics