MDS 05-3301A01, Rev. C
INIT
The
command is used to reset the radio's operating parameters to the
INIT
factory defaults. This may be helpful when trying to resolve configura-
tion problems that may have resulted from the entry of one or more
improper command settings. If you are unsure of which command set-
ting may have caused the problem, this command allows you to get back
to a known working state.
Use of the
command causes the changes shown in Table 8 to be
INIT
applied.
Table 8. Factory Default Values
Produced by INIT Command
For all radios
Device operation
RF output power
CTS delay
DATA INTERFACE port
Remote radios
Transmitter
test frequency
Receiver
test frequency
Master radios
Transmitter
test frequency
Receiver
test frequency
Skipped frequencies
Hop time
Simplex/duplex
operation
Buffer mode
MODE [M, R, R-M]
The
command sets or displays the operating mode of the radio. A
MODE
master radio is designated by an
MDS 9810 Installation and Operation Guide
Default Setting
DCE
30 dBm (1 watt)
0
(CTS is continuously
asserted)
4800 baud
8 data bits
no parity
1 stop bit
Per factory default
Per factory default
Per factory default
Per factory default
None (radio will hop
across all 1019
frequencies)
Normal (80 ms per hop)
Half-duplex
Seamless data mode
enabled
; a remote is designated by an
M
Corresponding
Command
DEVICE DCE
PWR 30
CTS 0
BAUD 4800 8N1
TX xxx
RX xxx
TX xxx
RX xxx
SKIP NONE
HOPTIME NORMAL
SIMPLEX OFF
BUFF ON
.
R
41