AFG3000 Series Arbitrary/Function Generators Service Manual
Table 6-4: Error codes (cont.)
Error code Description
--- Diagnostics ---
2100
Calibration data not found
2101
Calibration data checksum
2102
Calibration data invalid
2201
ASIC1 memory failure
2202
ASIC2 memory failure
2203
ASIC1 Overheat
2204
ASIC2 Overheat
--- Output Diagnostics ---
2301
CH1 Internal offset failure
2302
CH2 Internal offset failure
2303
CH1 Output offset failure
2304
CH2 Output offset failure
2305
CH1 Output gain failure
2306
CH2 Output gain failure
2401
CH1 x3dB attenuator failure
2402
CH2 x3dB attenuator failure
2403
CH1 x6dB attenuator failure
2404
CH2 x6dB attenuator failure
2405
CH1 x10dB attenuator failure
2406
CH2 x10dB attenuator failure
2407
CH1 x20dB 1 attenuator failure
2408
CH2 x20dB 1 attenuator failure
2409
CH1 x20dB 2 attenuator failure
2410
CH2 x20dB 2 attenuator failure
2411
CH1 Filter failure
2412
CH2 Filter failure
2413
CH1 x20dB 3 attenuator failure
2501
CH1 Sine Flatness failure
2502
CH2 Sine Flatness failure
Troubleshooting
Related module
A72
A72
A72
A1x/A3x/A4x
A12/A32/A42
A1x/A3x/A4x
A12/A32/A42
A1x/A3x/A4x
A12/A32/A42
A1x/A3x/A4x/A51/A61
A12/A32/A42/A51/A61
A1x/A3x/A4x/A51/A61
A12/A32/A42/A51/A61
A1x/A3x/A4x
A12/A32/A42
A1x/A3x/A4x
A12/A32/A42
A1x/A3x/A4x
A12/A32/A42
A1x/A3x/A4x
A12/A32/A42
A1x/A3x/A4x
A12/A32/A42
A51/A61
A51/A61
A43
A1x/A3x/A4x/A51/A61
A12/A32/A42/A51/A61
6-31