VLT
6000/8000
Drive Status Bit
Definitions
Bit
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
Bit
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
Bit
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
MG.60.N1.22
- VLT is a registered Danfoss trademark
Value
0
32768
33 OFF
16384
32 OFF
8192
29 OFF
4096
27 OFF
2048
19 OFF
1024
18 OFF
512
17 OFF
256
16 OFF
128
no function
64
no function
32
no function
16
no function
8
no function
4
no function
2
no function
1
no function
nvoDigitalInput
Value
0
32768
Alarm
16384
Alarm
8192
Safety Open
4096
No Alarm
2048
not used
1024
not used
512
not used
256
no Warning
128
Not at Ref.
64
Hand Mode
32
Fr. Range Warn
16
Stopped
8
no used
4
normal
2
normal
1
normal
nvoStatusWord
Value
0
32768
normal
16384
normal
8192
normal
4096
normal
2048
normal
1024
normal
512
normal
256
normal
128
normal
64
normal
32
normal
16
normal
8
normal
4
normal
2
normal
1
normal
nvoWarning1
VLT
®
5000 / VLT
1
Bit
33 ON
00
32 ON
01
29 ON
02
27 ON
03
19 ON
04
18 ON
05
17 ON
06
16 ON
07
08
09
10
11
12
13
14
15
1
Bit
Ctrl. Ready
00
Drive Ready
01
Safety Closed
02
Alarm
03
04
05
06
Warning
07
at Ref.
08
Auto Mode
09
Freq. in Range
10
Running
11
12
Voltage Warn.
13
Current lim.
14
Therm. Warning
15
1
Bit
Ref. High
00
Ctrl. Crd. Fault
01
Pwr. Crd. Fault
02
HPFB Timeout
03
RS-485 Timeout
04
Overcurrent
05
Current limit
06
Thermistor O.T.
07
Motor O.T.
08
Inverter O.T.
09
U.V. Alarm
10
O.V. Alarm
11
U.V. Warning
12
O.V. Warning
13
Input Phase Loss
14
Live Zero
15
®
6000
HVAC / VLT
®
8000 AQUA
Value
0
32768
no function
16384
no function
8192
no function
4096
no function
2048
no function
1024
no function
512
no function
256
no function
128
no function
64
no function
32
no function
16
no function
8
no function
4
Stopped
2
No Warning
1
no Alarm
nvoDrvStatus
Value
0
32768
normal
16384
normal
8192
normal
4096
normal
2048
normal
1024
normal
512
normal
256
normal
128
normal
64
normal
32
normal
16
normal
8
normal
4
normal
2
normal
1
normal
nvoAlarmWord
Value
0
32768
normal
16384
normal
8192
normal
4096
normal
2048
normal
1024
normal
512
normal
256
no Ramp
128
Forward
64
not at Ref.
32
Stopped
16
Remote Ref.
8
normal
4
Auto Start/stop
2
normal
1 Run Permission
nvoWarning2
1
Running
Warning
Alarm
1
Unknown Fault
Trip Lock
AMA Fault
HPFB Timeout
RS-485 Timeout
ASIC Fault
Short circuit
SMPS Fault
Ground Fault
Overcurrent
Current limit
Mtr. Thermistor
Motor thermal
Undervoltage
Overvoltage
In. Phase loss
1
Autoramping
Start Delay
Sleep Boost
Sleep
AMA Done
AMA Running
Rev. Start
Ramping
Reverse
at Reference
Running
Local Ref.
OFF (HOA)
Hand
Run Request
no Run Perm.
31
Need help?
Do you have a question about the VLT 5000 and is the answer not in the manual?
Questions and answers