Wiring diagram M12 connector (cable end)
You will need to assemble your reader cable with a suitable connector that fits the interface
shown above. Keep to the following wiring diagram:
Figure 5-40
5.7.1.5

Connection scheme for the digital I/O interface

Connection possibilities
You can connect the RF680R reader in different ways. In general, the outputs and inputs
should be connected as follows:
Output Outport (0), (1), (2), (3)
● Each output is rated for 0.5 A current and is electronically protected.
● 4 digital outputs can be operated simultaneously each with up to 0.5 A (up to 1.0 A in
total).
● The outputs are optically isolated through optocouplers.
Input Inport (0), (1), (2), (3)
● The inputs are optically isolated through optocouplers.
● Level Low 0 ... 3 V; High 3.6 ... 24 V
● Sampling rate < 20 ms
The following diagrams illustrate various connection possibilities.
SIMATIC RF600
System Manual, xx/2014, J31069-D0171-U001-A15-7618
M12 connector wiring diagram
Readers
5.7 RF680R reader
201