5.7.1.6
Pin assignment of the RS-422 interface
Pin
5.7.1.7
Pin assignment for Industrial Ethernet interface
View of M12 plug, 4-pin, D coding
(wiring side)
5.7.1.8
Grounding connection
The RF680R can be electrically connected to the ground potential with a contact washer.
The tightening torque must be increased in this case to ensure that electrical contact is made
(2.7 Nm).
Hazardous voltage due to lightning strikes
Death or serious injury may occur as a result of lightning strikes to antennas mounted
outside buildings.
If the reader is operated with antennas mounted outside buildings, it is imperative that the
reader is electrically connected to the ground potential.
SIMATIC RF600
System Manual, xx/2014, J31069-D0171-U001-A15-7618
Pin
Device end
8-pin M12
1
2
3
4
5
6
7
8
WARNING
Assignment
+ 24 V
- Transmit
0 V
+ Transmit
+ Receive
- Receive
Unassigned
Earth (shield)
Pin
Pin assignment
1
Data line TxP
2
Data line RxP
3
Data line TxN
4
Data line RxN
Readers
5.7 RF680R reader
207