Readers
5.5 RF650R reader
5.5.1.3
Status display
The device is equipped with 7 three-colored LEDs. The operating statuses of the reader are
displayed by the "RUN/STOP", "ERROR", "MAINT" and "PRESENCE" LEDs. The LEDs can
be lit green, red or orange. The meaning of the display changes according to the color and
status (on, off, flashing) of the LED:
R/S
ERR
-
-
-
-
-
-
-
-
-
For more detailed information on the flash codes of the reader, refer to the section LED
displays RF650R/RF680R/RF685R (Page 480).
5.5.1.4
Pin assignment of the digital I/O interface
View of socket (reader end)
Table 5- 19
M12 socket (reader end)
160
MT
PRE
Meaning
The device is turned off.
The device is starting up.
-
-
The device is ready for operation. The connection is established.
-
-
The device is working. Transponder data can be read or written.
-
-
There is an error.
-
Maintenance work required.
-
There is transponder in the antenna field.
-
There are multiple transponders in the antenna field.
Pin
1
2
3
4
5
6
7
8
9
10
11
12
Pin assignment
GND (output for supply of digital inputs/outputs [not
electrically isolated])
VCC (output for supply of digital inputs/outputs [not electrically
isolated])
DO Common / Outport Common
DO 0 / Outport 00
DO 1 / Outport 01
DO 2 / Outport 02
DO 3 / Outport 03
DI 0 / Inport 00
DI Common / Inport Common
DI 1 / Inport 01
DI 2 / Inport 02
DI 3 / Inport 03
System Manual, xx/2014, J31069-D0171-U001-A15-7618