Readers
5.5 RF650R reader
5.5.1.8
Grounding connection
The RF650R can be electrically connected to the ground potential with a contact washer.
The tightening torque must be increased in this case to ensure that electrical contact is made
(2.7 Nm).
Hazardous voltage due to lightning strikes
Death or serious injury may occur as a result of lightning strikes to antennas mounted
outside buildings.
If the reader is operated with antennas mounted outside buildings, it is imperative that the
reader is electrically connected to the ground potential.
NOTICE
Installation only in protected areas
The antenna can be installed in the protected part of a building. When implementing your
lightning protection concept, make sure you adhere to the VDE 0182 or IEC 62305
standards.
Ground connection
168
WARNING
(a)
Hexagon-head screw
(b)
Flat washer
(c)
Cable lug
(d)
Contact washer:
Use contact washers according to the
Siemens standard SN 70093-6-FSt-flNnnc-
480h for ground connection,
Siemens item no.: H70093-A60-Z3
System Manual, xx/2014, J31069-D0171-U001-A15-7618
SIMATIC RF600